Search found 1054 matches

by archive
Sun Feb 18, 2007 3:30 pm
Forum: Coleman Service & Repair
Topic: Induced Draft Blower Motor Runs Constantly
Replies: 4
Views: 9466

Hey Robert, thanks again. It was the Booster Relay. I finally got some time to get a better look at the heater. When the Heater turned off and the Induced Draft Blower Motor, I wiggled the Booster Relay, and it clicked and the motor turned off. So I removed the Booster relay and opened it up and rep...
by archive
Sun Feb 18, 2007 3:29 pm
Forum: Coleman Service & Repair
Topic: Induced Draft Blower Motor Runs Constantly
Replies: 4
Views: 9466

Hi,

Go to below link and scroll down to Booster Relay

#7956-3671 @ $23.56 + $6 shipping. Click on pic

for enlarged view.

It is inside Control Box next to Transformer.

Check that first for problem.

It can be ordered from the link if needed.

Take care and best wishes,
Robert
by archive
Sun Feb 18, 2007 3:29 pm
Forum: Coleman Service & Repair
Topic: Induced Draft Blower Motor Runs Constantly
Replies: 4
Views: 9466

I believe the switch is a proving switch. It proves to the circuit board that there is a draft going into the combustion chamber and that in turn tells the circuit board it is OK to light off the burner. The motor is running because it is getting a signal from the circuit board telling the motor to ...
by archive
Sun Feb 18, 2007 3:28 pm
Forum: Coleman Service & Repair
Topic: Induced Draft Blower Motor Runs Constantly
Replies: 4
Views: 9466

Induced Draft Blower Motor Runs Constantly

Well my Induced Draft Blower Motor is running constantly. I gotta Direct Vent Forced Air System model number DGAT070BDC. I took a quick look at the schematics I am getting that the Centrifugal switch is within the Induced Draft Blower Motor "housing". My blue wire runs from "TH" ...