Sometimes the furnace seems to get stuck and it keeps going off and on, off and on
What is going off and on the blower or the burner?
Search found 292 matches
- Thu Nov 22, 2007 7:58 pm
- Forum: Coleman Service & Repair
- Topic: Coleman heater gets stuck going off and on...
- Replies: 3
- Views: 2671
- Thu Nov 22, 2007 7:56 pm
- Forum: Coleman Service & Repair
- Topic: Coleman EB17A electric furnace
- Replies: 5
- Views: 5246
RE: Coleman EB17A electric furnace
Sounds like a sequencer problem.
part number
3115-3571
OR fan relay 3110-3301
part number
3115-3571
OR fan relay 3110-3301
- Thu Nov 22, 2007 10:48 am
- Forum: All Other HVAC Questions
- Topic: Water Heater pilot
- Replies: 6
- Views: 3849
- Thu Nov 22, 2007 2:27 am
- Forum: All Other HVAC Questions
- Topic: Water Heater pilot
- Replies: 6
- Views: 3849
RE: Water Heater pilot
There is really no test for the pilot orifice it is perfectly clean or is partially restricted. You have to take it apart to check this. Combustion air is the air that is burnt by the gas flame in the water heater. it takes a lot of air to burn clean and with no problems. You will notice somewhere a...
- Thu Nov 22, 2007 1:34 am
- Forum: All Other HVAC Questions
- Topic: Water Heater pilot
- Replies: 6
- Views: 3849
If a downdraft from the vent going thru the roof is causing this problem something is wrong with the vent system. Has this just started? Your pilot orifice might be partially plugged causing a short or insufficient flame. Does your water heater have enough combustion air for it to burn well when lit...
- Thu Nov 22, 2007 1:30 am
- Forum: Nordyne Service & Repair
- Topic: CONVERT NORDYNE FURNACE FROM NATURAL GAS TO PROPANE
- Replies: 4
- Views: 7466
- Wed Nov 21, 2007 2:06 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm Gas Furnace. Blower coming on intermittently
- Replies: 8
- Views: 10064
- Wed Nov 21, 2007 9:35 am
- Forum: Coleman Service & Repair
- Topic: Coleman Red T DGAA070BDTA Igniter burnout
- Replies: 4
- Views: 4174
In all the many years in the HVAC biz I have never had a problem with ignitors like you have. ((they have a website at www.ignitersdirect.com and are warranted for 3 years)) Looks like you can send them back and get a free one under the warrenty at least. BTW there is a cure for what you are talking...
- Wed Nov 21, 2007 9:18 am
- Forum: Service & Repair of Other Brands
- Topic: No heat on one side.
- Replies: 1
- Views: 3591
RE: No heat on one side.
More than likely the jumper duct has come loose under your home.
- Wed Nov 21, 2007 9:07 am
- Forum: Nordyne Service & Repair
- Topic: Intertherm Gas Furnace. Blower coming on intermittently
- Replies: 8
- Views: 10064
RE: Intertherm Gas Furnace. Blower coming on intermittently
Sounds like the combination fan and limit control. NOTE: this control controls the operation of the fan depending upon how much heat is in the furnace. It turns the fan off or on depending upon the furnace temp. More than likely yours is out of calibration BUT I would check the following before orde...
- Wed Nov 21, 2007 8:45 am
- Forum: Coleman Service & Repair
- Topic: Coleman 3500a816 no fan no power out of transformer
- Replies: 1
- Views: 1973
Your part number is
621299 Transformer = 3400-384
order on this page (top right side)
http://www.mobilehomerepair.com/ColemanElec.html
Thank you and have a great Thanksgiving.
621299 Transformer = 3400-384
order on this page (top right side)
http://www.mobilehomerepair.com/ColemanElec.html
Thank you and have a great Thanksgiving.
- Wed Nov 21, 2007 8:37 am
- Forum: Coleman Service & Repair
- Topic: Coleman Red T DGAA070BDTA Igniter burnout
- Replies: 4
- Views: 4174
RE: Coleman Red T DGAA070BDTA Igniter burnout
If you can find one of these that will fit your burner get one. They do last longer. http://www.white-rodgers.com/wrdhom/pdfs/sell_sheets/wr_7071_1_21D64_2_NitrideMod_SS.pdf Cross refrence http://www.white-rodgers.com/wrdhom/pdfs/instruction_sheets/0037-6299.pdf You might also check with Robert on t...
- Sun Nov 18, 2007 12:22 pm
- Forum: Nordyne Service & Repair
- Topic: Combustion blower motor on CMF 100-PO runs continuously
- Replies: 4
- Views: 5196
RE: Combustion blower motor on CMF 100-PO runs continuously
This is taken direct from Nordyne/Miller Note: Type 12S Series are time delay relays used as sequencers on electric heating products. (((12S includes the part number you were asking about 105144000 time delay relay for electric furnaces only. ))) The time delay you are talking about is for a electri...
- Thu Nov 15, 2007 3:21 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Presidential Furnace
- Replies: 3
- Views: 2980
RE: Coleman Presidential Furnace
Usually the transformer makes that jind of noise. It is common.
- Thu Nov 15, 2007 6:45 am
- Forum: Coleman Service & Repair
- Topic: Colemman 7956-856 blower stays on
- Replies: 6
- Views: 3808
RE: Colemman 7956-856 blower stays on
Robert ??
What I am getting for this unit is a
6313-2281 blower relay
OR
a 7975-3281 fan and limit.
If the fan limit is tripped will the blower run all the time on this model?
I wounder if this is a 2 wire system?
I hate to give the wrong info.
What I am getting for this unit is a
6313-2281 blower relay
OR
a 7975-3281 fan and limit.
If the fan limit is tripped will the blower run all the time on this model?
I wounder if this is a 2 wire system?
I hate to give the wrong info.