- Fri Jan 20, 2012 11:46 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne E2EH 015HA fan will not work in auto postion
- Replies: 17
- Views: 24043
Re: Nordyne E2EH 015HA fan will not work in auto postion
You mention a rocker switch on a panel, is there also a Heat/Cool rocker switch on the same panel? Sounds like the blower relay is bad.
- Fri Jan 20, 2012 11:41 am
- Forum: Nordyne Service & Repair
- Topic: M1MB07 Series Intertherm Orifice
- Replies: 1
- Views: 1987
Re: M1MB07 Series Intertherm Orifice
It is screwed into a small pipe coming out of the control valve inside the body of the furnace. Basically it's where the gas comes out to be burned to produce heat in the heat exchanger. Actually very few problems associated with the oriface. Only one I know is a spider web, provided the furnace is ...
- Thu Jan 19, 2012 7:58 pm
- Forum: Mobile Home Repair
- Topic: Old mobile home roof problem
- Replies: 6
- Views: 4539
Re: Old mobile home roof problem
Repairing the old stuff is a waste of time. The lumber is way dried out and really was a crap system when it was originally installed. Did many of these when I was younger. We always cut and installed new rafters out of either 2x6 or 2x8s depending on the height of the original truss style rafters. ...
- Thu Jan 19, 2012 7:37 pm
- Forum: Mobile Home Repair
- Topic: Draining water lines
- Replies: 7
- Views: 2200
Re: Draining water lines
If you have a dishwasher, washing machine or ice maker be sure to empty those as well. Also run some antifreeze through the dishwasher and washing machine drain cycles. A gallon each will protect them.
- Thu Jan 19, 2012 7:31 pm
- Forum: Mobile Home Repair
- Topic: Really need help!
- Replies: 17
- Views: 4406
Re: Really need help!
Metal roof or shingled roof?
- Thu Jan 19, 2012 7:24 pm
- Forum: Mobile Home Repair
- Topic: Kitchen faucet lines.
- Replies: 12
- Views: 5738
Re: Kitchen faucet lines.
Unless you have the crimp tool for the rings on the PB and Pex tubing this job is better left to a plumber that does. Standard SS hose clamps will not apply enough pressure to properly seal the fittings and I wouldn't trust the slip fit fittings that are available unless it is a "no choice"...
- Wed Jan 18, 2012 5:25 pm
- Forum: Nordyne Service & Repair
- Topic: INTERTHERM GAS VALVE PROBLEMS ????
- Replies: 13
- Views: 14076
Re: INTERTHERM GAS VALVE PROBLEMS ????
Hoppy if the control valve isn't opening fully there will be a tall yellow flame when on LP gas. Should look sort of lazy as well. That is a slow opening/staging valve on that furnace, actually I haven't ever seen a mobile home furnace that wasn't like that. You can try whacking/tapping the side of ...
- Wed Jan 18, 2012 9:41 am
- Forum: Coleman Service & Repair
- Topic: little to no heat
- Replies: 6
- Views: 3922
Re: little to no heat
My suggestion is as above: check main burner oriface for spider web.
- Wed Jan 18, 2012 9:39 am
- Forum: Coleman Service & Repair
- Topic: DGAT056BDD first two flash, now one flash
- Replies: 1
- Views: 2293
Re: DGAT056BDD first two flash, now one flash
If everything is "clicking" correctly and igniter is not glowing, replace igniter. I would test for power to the igniter first with a multitester. You should get 120v to the igniter terminals/plug at some point during the start up process. If you have power then igniter is bad.
- Wed Jan 18, 2012 9:31 am
- Forum: Nordyne Service & Repair
- Topic: INTERTHERM GAS VALVE PROBLEMS ????
- Replies: 13
- Views: 14076
Re: INTERTHERM GAS VALVE PROBLEMS ????
Very strange for valve to fail in "on" position. Checking pressures in and out will let you know what valve is doing. If water column pressure going in is good and out is wrong then valve is bad. Correct pressures are listed on furnace data plate. 20 years....might also check the heat exch...
- Wed Jan 18, 2012 9:25 am
- Forum: Nordyne Service & Repair
- Topic: How hot should the furnace be getting?
- Replies: 5
- Views: 11004
Re: How hot should the furnace be getting?
My fault...they are still available. Just don't see any "newer" ones in my area. Use a mirror and flashlight to see if the duct work is clear. Are the fins on the floor registers bent closed? Pull them all out for a day or 2 to see if that helps. Any chance there is a solid door as access ...
- Fri Jan 13, 2012 1:25 pm
- Forum: Nordyne Service & Repair
- Topic: How hot should the furnace be getting?
- Replies: 5
- Views: 11004
Re: How hot should the furnace be getting?
That's high but there's another problem you're not catching, not moving enough air through the furnace, hole in the heat exchanger, blockage in vents, etc. Did you ever replace the blower motor? Was it the right one? Has the heat exchanger been inspected? That's an OLD unit. Is the asbestos pot (com...
- Fri Jan 13, 2012 1:04 pm
- Forum: Nordyne Service & Repair
- Topic: INTERTHERM GAS VALVE PROBLEMS ????
- Replies: 13
- Views: 14076
Re: INTERTHERM GAS VALVE PROBLEMS ????
Sounds like the control valve is working properly. Can you check water column pressure into and out of the control valve? Easier yet, was the furnace set up properly to run LP gas? Natural gas operates at lower pressures and will have larger orifaces. Are the proper orifaces in place in the pilot an...
- Wed Oct 26, 2011 11:37 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne-intertherm model MMHA-090AA
- Replies: 1
- Views: 2717
Re: Nordyne-intertherm model MMHA-090AA
2 blinks is a flash code. Should be a data sheet attached someplace on the furnace near the control box that states the flash code status. Could also be on the backside of the electronics cover panel for the furnace. Locate that and it will help you diagnose your problem.
- Wed Oct 26, 2011 11:32 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne M1MB 077A BW Won't stay lit
- Replies: 2
- Views: 6441
Re: Nordyne M1MB 077A BW Won't stay lit
Yes igniter is flame sensor. If burner ignites then goes out shortly afterwards either the igniter is positioned incorrectly or there may be a spider web in the main burner oriface that is blocking the flow of gas to support the flame.