Search found 6413 matches

by Robert
Fri Feb 11, 2011 11:31 pm
Forum: Nordyne Service & Repair
Topic: Disconnect Furnace to Replace Particle Board Flooring
Replies: 5
Views: 3598

Re: Disconnect Furnace to Replace Particle Board Flooring

Hi,

You're very welcome, happy to help.



Thanks,
Robert
by Robert
Fri Feb 11, 2011 6:54 pm
Forum: Nordyne Service & Repair
Topic: Disconnect Furnace to Replace Particle Board Flooring
Replies: 5
Views: 3598

Re: Disconnect Furnace to Replace Particle Board Flooring

Hi,

There may also be L brackets to secure furnace to wall. IF you have a/c, you'll need an hvac tech to handle the a-coil, drain line and refrigerant lines.


Thanks,
Robert
by Robert
Fri Feb 11, 2011 4:32 pm
Forum: Nordyne Service & Repair
Topic: Disconnect Furnace to Replace Particle Board Flooring
Replies: 5
Views: 3598

Re: Disconnect Furnace to Replace Particle Board Flooring

Hi,

What is furnace model number ? Do you have a/c A-Coil also ?


Thanks,
Robert
by Robert
Thu Feb 10, 2011 4:32 pm
Forum: Coleman Service & Repair
Topic: blower motor
Replies: 5
Views: 2768

Re: blower motor

Hi,

Trace the blower motor wires used at that time back to molex connector. Disconnect the plug and find corresponding wire holes in the other side of plug. Test across to see if the motor is getting 120VAC at time it should be running.




Thanks,
Robert
by Robert
Wed Feb 09, 2011 10:13 pm
Forum: Coleman Service & Repair
Topic: Blower
Replies: 13
Views: 6295

Re: Blower

Hi,

For auto mode:


With a NO CALL at t-stat, should have 24VAC across RH and W.


With a CALL for heat, it should change to 0VAC across RH and W.


For Fan ON CONT. mode:

NO CALL = 24VAC across RH and G

CALL = 0VAC across RH and G



Thanks,
Robert
by Robert
Wed Feb 09, 2011 10:11 pm
Forum: Coleman Service & Repair
Topic: Blower
Replies: 13
Views: 6295

Re: Blower

Hi,

For auto mode:


With a NO CALL at t-stat, should have 24VAC across RH and W.


With a CALL for heat, it should change to 0VAC across RH and W.


For Fan ON CONT. mode:

NO CALL = 24VAC across RH and G

CALL = 0VAC across RH and G



Thanks,
Robert
by Robert
Wed Feb 09, 2011 8:16 pm
Forum: Off Topic Discussions
Topic: Super Bowl 45
Replies: 14
Views: 10438

Re: Super Bowl 45

,that wasn't my idea of superbowl quality game or anything :wink: I agree. Steelers were a long way from the best game of their season. Congrats Pac Fans!! I disagree JD. That was a veteran team with SB exp. and a veteran coach with SB experience. Playing in game 19, all the kinks were long worked ...
by Robert
Wed Feb 09, 2011 3:25 pm
Forum: Nordyne Service & Repair
Topic: Intertherm FEH015HA-04 Wont shut down.
Replies: 1
Views: 2507

Re: Intertherm FEH015HA-04 Wont shut down.

Hi,


Most likely a stuck sequencer.


Sequencer # 901075 can be seen and ordered from here by paging down :

http://www.aberdeenhomerepair.com/store ... er-3-stage




Thanks,
Robert
by Robert
Wed Feb 09, 2011 3:21 pm
Forum: Coleman Service & Repair
Topic: Blower
Replies: 13
Views: 6295

Re: Blower

Hi,


Possibly a bad thermostat or a loose wire connection by what you described. Would have to test it to know for sure.



Thanks,
Robert
by Robert
Wed Feb 09, 2011 3:17 pm
Forum: Coleman Service & Repair
Topic: blower motor
Replies: 5
Views: 2768

Re: blower motor

Hi,

Will need complete furnace model number. Ensure the filter, motor. blower wheel and a/c a-coil if you have a/c are all clean.


Make sure there are no blockages in duct.


IF all that is good to go, then most likely going to need a new motor.



Thanks,
Robert
by Robert
Tue Feb 08, 2011 10:53 pm
Forum: All Other HVAC Questions
Topic: Was going to update my post to help others
Replies: 1
Views: 2062

Re: Was going to update my post to help others

Hi Scott,

Had to start locking them due to a lot of spammers coming into old posts/threads.


Been doing this for so long on here, about any problem known is in here somewhere if they search.


Glad you got it going and you're very welcome, happy to help.



Thanks,
Robert
by Robert
Tue Feb 08, 2011 10:42 pm
Forum: Coleman Service & Repair
Topic: Furnace won't stay fired
Replies: 1
Views: 1601

Re: Furnace won't stay fired

Hi,

Have very little experience with oil furnaces, so will leave this here for others who do to try and help.


Can say though that you should not be using the reset to keep it going. Depending on the problem, that can lead to a serious problem.




Thanks,
Robert
by Robert
Tue Feb 08, 2011 12:18 am
Forum: Nordyne Service & Repair
Topic: Model:FEH-020HR-03
Replies: 2
Views: 3573

Re: Model:FEH-020HR-03

Hi,

Can you determine if the OD of the coils are 1/2" or 3/4" ?


You have four 5kw coils, 10kw for each assembly.


I would also be getting a large refund from the repair guy that took $350 to disconnect a coil.



Thanks,
Robert
by Robert
Mon Feb 07, 2011 5:38 pm
Forum: Nordyne Service & Repair
Topic: What do I have?
Replies: 1
Views: 3117

Re: What do I have?

Hi, 1- No 2- No 3- Hook it up same as old. Red/RH, Yellow/Y, Green/G and White/W . Will need to be battery operated or will need a 5th common wire from transformer to thermostat C terminal. 4- You have a 4 ton / 10 SEER split air conditioning condensing unit and an Electric Furnace indoors with an a...
by Robert
Mon Feb 07, 2011 5:28 pm
Forum: Coleman Service & Repair
Topic: Deluxe Blend Air II Damper Motor
Replies: 16
Views: 9189

Re: Deluxe Blend Air II Damper Motor

Hi David,

You're very welcome, happy to help.




Thanks,
Robert