Re: Siding Questions

Currently, the T1-11 is acting as a sheathing material and a finish. If you remove it, I recommend you install sheathing as it provides structural rigidity. Then you are right back to adding the weight savings back.
by flcruising
Fri Jan 27, 2012 10:43 am
Forum: Mobile Home Repair
Topic: How to create lifts for sagging wall edges?
Replies: 10
Views: 33336

Re: How to create lifts for sagging wall edges?

I can't tell if you mentioned if your home is a single or double wide... If my understanding is correct, your home's floor joists are bowed up in the middle (between the support beams) and sagging down at the outside walls? If this is the case, the key to a solution is to (as mentioned) support the ...
by flcruising
Fri Jan 27, 2012 9:53 am
Forum: Nordyne Service & Repair
Topic: Nordyne E2EH 015HA fan will not work in auto postion
Replies: 17
Views: 22305

Re: Nordyne E2EH 015HA fan will not work in auto postion

Does the yellow wire from the fan switch connect to Sequencer #1?
by flcruising
Tue Jan 24, 2012 8:54 pm
Forum: Nordyne Service & Repair
Topic: Nordyne E2EH 015HA fan will not work in auto postion
Replies: 17
Views: 22305

Re: Nordyne E2EH 015HA fan will not work in auto postion

Yes, it appears you don't have a relay. But also, the model number given is for a heat only unit, therefore the heat pump system (mentioned in your other post) is probably in control of the blower anyways. You can try and check the wiring against this - http://www.nordyne.com/Literature/359a.pdf#pag...
by flcruising
Tue Jan 24, 2012 1:20 pm
Forum: Nordyne Service & Repair
Topic: Nordyne E2EH 015HA fan will not work in auto postion
Replies: 17
Views: 22305

Re: Nordyne E2EH 015HA fan will not work in auto postion

As DaleM mentioned, it sounds like it's either the blower relay or the t-stat.
by flcruising
Tue Jan 24, 2012 12:56 pm
Forum: Nordyne Service & Repair
Topic: please help!!!! blower only runs in on position
Replies: 1
Views: 2128

Re: please help!!!! blower only runs in on position

Please don't double-post the same issue.
Continue your troubleshooting conversation here - https://www.mobilehomerepair.com/phpbb/v ... f=2&t=9001
by flcruising
Thu Jan 19, 2012 1:39 pm
Forum: Nordyne Service & Repair
Topic: How hot should the furnace be getting?
Replies: 5
Views: 10931

Re: How hot should the furnace be getting?

Does it trip the new high limit switch? The unit could be oversized for your ductwork and home, or as DaleM says, there's a restriction. A blockage that large should be noticeable, as-in not much flow coming from vents. If the flow is adequate, then the burner/heat exchanger should be the next place...
by flcruising
Mon Jan 16, 2012 1:39 pm
Forum: Coleman Service & Repair
Topic: UPDATE - Coleman 3500a812: Heat and blower staying on
Replies: 5
Views: 6174

Re: UPDATE - Coleman 3500a812: Heat and blower staying on

I don't have a manual or wiring diagram for your unit, but when you mention the reversing relay, are you referring to the fan relay? Can you pull the t-stat and report back the wires present? Also, trying to clarify what the issue now is... You have sufficient heat and the blower runs fine at initia...
by flcruising
Sat Jan 14, 2012 11:10 am
Forum: Service & Repair of Other Brands
Topic: Need some assistance with an Intertherm FEH-012H
Replies: 4
Views: 17944

Re: Need some assistance with an Intertherm FEH-012H

Check for voltage on the element side of the sequencer circuit. This of course would require a multimeter.
by flcruising
Fri Jan 13, 2012 3:51 pm
Forum: Service & Repair of Other Brands
Topic: Need some assistance with an Intertherm FEH-012H
Replies: 4
Views: 17944

Re: Need some assistance with an Intertherm FEH-012H

Have you looked at the wiring inside the unit to make sure they are all connected? Look for any burnt wires as well.
by flcruising
Fri Jan 13, 2012 3:47 pm
Forum: Coleman Service & Repair
Topic: little to no heat
Replies: 6
Views: 3853

Re: little to no heat

Gas valve or partially clogged orifice may be not allowing the flame to reach optimal range.
by flcruising
Fri Jan 13, 2012 3:35 pm
Forum: Nordyne Service & Repair
Topic: Miller Electric Model # FEH017HA04
Replies: 1
Views: 2650

Re: Miller Electric Model # FEH017HA04

Not receiving power as in 110/220V not detected at the unit and the blower won't respond to the t-stat?

More information is needed. What was sparking?
by flcruising
Fri Jan 13, 2012 3:23 pm
Forum: All Other HVAC Questions
Topic: Install HW Baseboard in MH
Replies: 2
Views: 2987

Re: Install HW Baseboard in MH

I'm interested in the boiler setup you will have. My thoughts are this... The hydronic baseboard heaters should be fine, or radiators with covers. Sizing is everything, but I'm sure you know this since you've been through it before. But why go through the trouble of keeping the piping inside the hom...