Search found 742 matches

by Mark
Wed Oct 12, 2011 11:00 am
Forum: All Other HVAC Questions
Topic: Crossover duct
Replies: 5
Views: 3532

Re: Crossover duct

Hi,

Generally the flexible ductwork found here is what's recommended: http://www.aberdeenhomerepair.com/store ... 8/Ductwork

Mark
by Mark
Wed Oct 12, 2011 10:56 am
Forum: Coleman Service & Repair
Topic: Coleman DGAA070BDTA Not lighting up
Replies: 6
Views: 5392

Re: Coleman DGAA070BDTA Not lighting up

Hi, If the problem is worn-out parts (and not a plugged airway or cracked heat exchanger), then there's probably 1 of 2 parts that you need. When you first turn the thermostat on, you should hear the booster motor running. If it's not running, it may have taken on some moisture over the summer and g...
by Mark
Wed Oct 12, 2011 10:50 am
Forum: Coleman Service & Repair
Topic: Coleman EB10B Filter
Replies: 1
Views: 1987

Re: Coleman EB10B Filter

Hi,

Should be a 16x20 filter on top.

Mark
by Mark
Tue Oct 11, 2011 4:21 pm
Forum: All Other HVAC Questions
Topic: Furnace Replacement
Replies: 1
Views: 2214

Re: Furnace Replacement

Hi, Compared to a gas unit, electric furnaces are fairly easy to replace. Like you said, you basically shut off the power, remove the power wires and thermostat wires, disconnect from ductwork and take out. Put in the new following the same steps in reverse. If you have air conditioning attached to ...
by Mark
Tue Oct 11, 2011 4:18 pm
Forum: Service & Repair of Other Brands
Topic: intertherm ezeb-15hb buzz
Replies: 1
Views: 15190

Re: intertherm ezeb-15hb buzz

Sure it's not a transformer or contactor that's buzzing?

Mark
by Mark
Mon Oct 10, 2011 11:13 pm
Forum: Coleman Service & Repair
Topic: HELP PLEASE !! COLEMAN DGAA708BDTA
Replies: 3
Views: 3069

Re: HELP PLEASE !! COLEMAN DGAA708BDTA

With the power off, removing the black box and nudging it with a screwdriver may be enough to get it unstuck and running. If you are having to do that every year, you are getting moisture in there during the summer and its causing some rust. Eventually it'll need to be replaced. To replace you need ...
by Mark
Mon Oct 10, 2011 11:11 pm
Forum: Coleman Service & Repair
Topic: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)
Replies: 4
Views: 3632

Re: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)

Hi, You can test the booster assembly the same way. Run power directly to the 2 wires and see if it runs. Yes, you need to remove or loosen all that stuff below so the draft booster can slide down and out. The little black box is included.

Mark
by Mark
Sun Oct 09, 2011 8:58 pm
Forum: Coleman Service & Repair
Topic: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)
Replies: 4
Views: 3632

Re: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)

If the booster motor did not turn on instantly, replace it. If it's not running, it can't trip the pressure switch which is causing the fault code on the control board. You can see and order the booster assembly for your furnace here: http://www.aberdeenhomerepair.com/store/product/2339/373-19801-82...
by Mark
Sat Oct 08, 2011 10:15 pm
Forum: Nordyne Service & Repair
Topic: Blower Questions E1EH1-015A
Replies: 1
Views: 2584

Re: Blower Questions E1EH1-015A

Remove the black wire and put the red wire in its place.

Mark
by Mark
Sat Oct 08, 2011 10:12 pm
Forum: Nordyne Service & Repair
Topic: Major problems with E1EH1-015A
Replies: 4
Views: 3974

Re: Major problems with E1EH1-015A

Hi,

Sorry about the slow response. Did you get things figured out?

Mark
by Mark
Sat Oct 08, 2011 10:10 pm
Forum: Coleman Service & Repair
Topic: furnance not igniting
Replies: 1
Views: 2178

Re: furnance not igniting

If you get a brief flame, try replacing or cleaning the flame sensor with a light touch of steel wool. Otherwise need to know more details.

Mark
by Mark
Sat Oct 08, 2011 10:08 pm
Forum: Coleman Service & Repair
Topic: coleman/evcon DGAT 070BDC , no power to the combustion motor
Replies: 3
Views: 3578

Re: coleman/evcon DGAT 070BDC , no power to the combustion m

Hooking wires together on the Centrifugal switch won't get the booster motor going. Spinning the motor may work the first couple seasons, but eventually the rust will take over and it's time for a new booster motor. Here you can see the booster motor for your furnace: http://www.aberdeenhomerepair.c...
by Mark
Sat Oct 08, 2011 9:59 pm
Forum: Coleman Service & Repair
Topic: HELP PLEASE !! COLEMAN DGAA708BDTA
Replies: 3
Views: 3069

Re: HELP PLEASE !! COLEMAN DGAA708BDTA

Sounds like the booster assembly finally died. Part # 373-19801-821. Can be seen here: http://www.aberdeenhomerepair.com/store ... oster-assy
by Mark
Sat Oct 08, 2011 9:55 pm
Forum: Coleman Service & Repair
Topic: DGAT056BDD Ignition Problem
Replies: 1
Views: 3795

Re: DGAT056BDD Ignition Problem

I would start by cleaning the flame sensor. If that doesn't solve the problem, then take a look at the board.

Mark
by Mark
Sat Oct 08, 2011 9:53 pm
Forum: Coleman Service & Repair
Topic: Booster Motor
Replies: 2
Views: 2593

Re: Booster Motor

Glad you got it figured out.

Mark