RE: Roof coatings

Only time will tell on the cracking part.
by hvac1000
Thu Oct 18, 2007 6:17 pm
Forum: Service & Repair of Other Brands
Topic: Miller furnace problem(s)
Replies: 4
Views: 14570

((and close it which kicks in the IDM (triggered by the button when door is shut) it will then continue to ignite and the blower starts. Thereafter it runs successfully for days or weeks again without ))

Could be this switch? Jump it out and run it for awhile to see if it is the problem.
by hvac1000
Thu Oct 18, 2007 6:12 pm
Forum: All Other HVAC Questions
Topic: Electric furnace cheaper than a propane furnace these days?
Replies: 19
Views: 15510

RE: Electric furnace cheaper than a propane furnace these da

That depends upon how big the electric furnace will be as far as KW is concerned. Remember also when changing over to a electric furnace that the electric service and indoor panel has to have the capacity to provide enough amps to the new electric furnace. We have electric furnaces in larger homes t...
by hvac1000
Thu Oct 18, 2007 1:07 pm
Forum: Decorating, Landscaping and Gardening
Topic: Backer for gas log stove
Replies: 4
Views: 2944

RE: Backer for gas log stove

Usually gas log stoves are not energy efficient this is just a fact that is why I said what I said. I have two wood fireplaces here and I know that it costs me more to use them than the heat I get. Did you do a cost analysis? How much is electric how much is gas? Did you figure electric at 100% effi...
by hvac1000
Thu Oct 18, 2007 9:47 am
Forum: Service & Repair of Other Brands
Topic: Furnace won't come on
Replies: 7
Views: 15303

RE: Furnace won't come on

Sometimes the elements droop down and touch ground. It could also be a defective power wire so check it over with the power off first just to see if everything electrical is up to spec. The breakers are plug in or bolt in depending upon the manufacturer. If the breakers in the furnace are not trippi...
by hvac1000
Wed Oct 17, 2007 4:38 pm
Forum: Off Topic Discussions
Topic: Christmas Ornament - B.A.S.S.
Replies: 4
Views: 3400

Does it talk like the bigger ones?
by hvac1000
Wed Oct 17, 2007 4:37 pm
Forum: Decorating, Landscaping and Gardening
Topic: Backer for gas log stove
Replies: 4
Views: 2944

Cheap cure is aluminum foil shinny side out. Now that is probably not what you wanted to hear but it is cheap and effective.

If you are trying to conserve energy do not run that stove. It probably is not very energy efficient. Just thought I would mention that fact.
by hvac1000
Wed Oct 17, 2007 4:31 pm
Forum: Mobile Home Repair
Topic: Roof coatings
Replies: 4
Views: 4617

Roof coatings

For years I coated roofs on our types of houses. Now I am to old and overweight to get on the roof so I have a young man at camp that does it for myself and other customers. Over the years we have used many brands of asphalt roof coatings some were good and some were to thin to do anything but give ...
by hvac1000
Wed Oct 17, 2007 4:16 pm
Forum: Service & Repair of Other Brands
Topic: Furnace won't come on
Replies: 7
Views: 15303

RE: Furnace won't come on

The circuit breakers in the panel could be weak or defective. I would check the furnace for any short circuits on the heater before I would replace the breakers. Usually when there is a breaker problem in the panel inside the home it is a heater circuit and not a breaker problem. Many manufactures u...
by hvac1000
Mon Oct 15, 2007 10:52 pm
Forum: Coleman Service & Repair
Topic: evcon furnace with motor constantly running
Replies: 32
Views: 19392

RE: evcon furnace with motor constantly running

Thank you Robert I never thought that someone would mistake a two wire tie in for two separate wires. LOL At least now it is straitened out.
by hvac1000
Mon Oct 15, 2007 8:49 pm
Forum: Coleman Service & Repair
Topic: evcon furnace with motor constantly running
Replies: 32
Views: 19392

RE: evcon furnace with motor constantly running

That is strange. Could be Robert will be along in a while. At this point I am kind of lost. Was there somekind of a part number on the old one? post all the numbers on the old one if you can.
by hvac1000
Mon Oct 15, 2007 8:25 am
Forum: Coleman Service & Repair
Topic: evcon furnace with motor constantly running
Replies: 32
Views: 19392

8665-309 this is 4 prong also. Where did you get it to be 5 prong?
by hvac1000
Mon Oct 15, 2007 3:31 am
Forum: Coleman Service & Repair
Topic: evcon furnace with motor constantly running
Replies: 32
Views: 19392

Re: RE: evcon furnace with motor constantly running

hvac1000 wrote:I will try to find a pic of relay

Image



Number 40 is booster relay
by hvac1000
Mon Oct 15, 2007 3:26 am
Forum: Coleman Service & Repair
Topic: evcon furnace with motor constantly running
Replies: 32
Views: 19392

RE: evcon furnace with motor constantly running

I will try to find a pic of relay
by hvac1000
Mon Oct 15, 2007 3:05 am
Forum: Coleman Service & Repair
Topic: evcon furnace with motor constantly running
Replies: 32
Views: 19392

Just looked it up again. The Booster relay will have 4 prongs. The fan blower has 5 prongs.

You need to find the 4 prong booster relay not the 5 prong blower relay.Wire it exactly like the old one.


Here is the wiring diagram.

http://www.mobilehomerepair.com/media/i ... 5-5701.pdf