- Wed Jan 26, 2011 9:25 pm
- Forum: Coleman Service & Repair
- Topic: Coleman heater keeps shutting off
- Replies: 8
- Views: 4305
Re: Coleman heater keeps shutting off
Hi Craig, The top switch is a fan Switch. The bottom is a lower limit switch. Fan Switch # 7975 - 3281 can be seen and ordered here by paging down : http://www.aberdeenhomerepair.com/store/product/2412/F110-20F--fan-switch-7975-3281 IF you need or wish to get the lower limit, after adding fan switch...
- Wed Jan 26, 2011 8:03 pm
- Forum: Coleman Service & Repair
- Topic: Coleman heater keeps shutting off
- Replies: 8
- Views: 4305
Re: Coleman heater keeps shutting off
Hi Craig,
What is the complete furnace model number ? Is the limit that is tripping up next to or attached to the blower housing ?
Or is it about midway of the furnace ?
Thanks,
Robert
What is the complete furnace model number ? Is the limit that is tripping up next to or attached to the blower housing ?
Or is it about midway of the furnace ?
Thanks,
Robert
- Wed Jan 26, 2011 7:05 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Evcon EB17B Serial#950531147
- Replies: 7
- Views: 3882
Re: Coleman Evcon EB17B Serial#950531147
Hi Zac,
Go to transformer and test Primary-Line side for 240vac across the two terminals.
Then go to other side, Secondary-Load side and test for 24vac.
Let me know what you get.
Thanks,
Robert
Go to transformer and test Primary-Line side for 240vac across the two terminals.
Then go to other side, Secondary-Load side and test for 24vac.
Let me know what you get.
Thanks,
Robert
- Wed Jan 26, 2011 5:30 am
- Forum: Coleman Service & Repair
- Topic: Coleman EB15B intermittent auto fan problem
- Replies: 13
- Views: 24494
Re: Coleman EB15B intermittent auto fan problem
You're very welcome, happy to help.
Thanks,
Robert
Thanks,
Robert
- Wed Jan 26, 2011 4:11 am
- Forum: Coleman Service & Repair
- Topic: Coleman furnace
- Replies: 3
- Views: 2782
Re: Coleman furnace
HI, What I was saying is that the ignitor could have been going bad earlier, but the inducer motor problem/pressure switch problem would override it and diagnostic light would show that first. Once you corrected that and got it going again, the ignitor problem surfaced on diagnostic light. IF it get...
- Tue Jan 25, 2011 8:44 pm
- Forum: Coleman Service & Repair
- Topic: Coleman EB15B intermittent auto fan problem
- Replies: 13
- Views: 24494
Re: Coleman EB15B intermittent auto fan problem
Hi,
This website, online store and the aberdeenhomerepair.com store are all owned by Mark Bower.
I do contracted work for him on here and through emails.
Thanks,
Robert
This website, online store and the aberdeenhomerepair.com store are all owned by Mark Bower.
I do contracted work for him on here and through emails.
Thanks,
Robert
- Tue Jan 25, 2011 7:39 pm
- Forum: Coleman Service & Repair
- Topic: Coleman EB15B intermittent auto fan problem
- Replies: 13
- Views: 24494
Re: Coleman EB15B intermittent auto fan problem
Hi,
The t-stat itself will often cause problems. Great ceiling fans, but not t-stats.
The sequencer test itself was all that was needed.
Thanks,
Robert
The t-stat itself will often cause problems. Great ceiling fans, but not t-stats.
The sequencer test itself was all that was needed.
Thanks,
Robert
- Tue Jan 25, 2011 7:33 pm
- Forum: All Other HVAC Questions
- Topic: More Specific Ductless/Mini Split AC Question
- Replies: 4
- Views: 3159
Re: More Specific Ductless/Mini Split AC Question
Hi,
You're very welcome, we're happy to help.
Take care and best wishes,
Robert
You're very welcome, we're happy to help.
Take care and best wishes,
Robert
- Tue Jan 25, 2011 7:29 pm
- Forum: Service & Repair of Other Brands
- Topic: Filter location for AGC100GAS
- Replies: 1
- Views: 15373
Re: Filter location for AGC100GAS
Hi,
Yes, it goes behind the upper louvered door.
Filter # 102957000
Filter Retainer # 302257000
Call Mark @ 605-229-2627 and see if he has those or can get them or a compatible replacement.
Thanks,
Robert
Yes, it goes behind the upper louvered door.
Filter # 102957000
Filter Retainer # 302257000
Call Mark @ 605-229-2627 and see if he has those or can get them or a compatible replacement.
Thanks,
Robert
- Tue Jan 25, 2011 6:57 pm
- Forum: Nordyne Service & Repair
- Topic: Hey everyone....
- Replies: 5
- Views: 3867
Re: Hey everyone....
Hi,
Do you still need any help with this ?
Thanks,
Robert
Do you still need any help with this ?
Thanks,
Robert
- Tue Jan 25, 2011 6:46 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne Intertherm E2EB-020HB
- Replies: 1
- Views: 3219
Re: Nordyne Intertherm E2EB-020HB
Hi, Your furnace has two contactors and two relays that together control the elements and the blower motor . The circuits can run through them even though that one may not actually control the circuit or component. Without thorough electrical testing, hard to say which one may be at fault or if it's...
- Tue Jan 25, 2011 5:22 pm
- Forum: Coleman Service & Repair
- Topic: Coleman EB15B intermittent auto fan problem
- Replies: 13
- Views: 24494
Re: Coleman EB15B intermittent auto fan problem
Hi, Sequencer is definitely bad. Sequencer # 3115 - 3571 can be seen and ordered from here by paging down: http://www.aberdeenhomerepair.com/store/product/2311/3115-3571-sequencer I would suggest replacing the Hunter t-stat with a Honeywell. IF you choose to remain with the Hunter, leave it set to H...
- Tue Jan 25, 2011 5:05 pm
- Forum: Coleman Service & Repair
- Topic: Coleman furnace
- Replies: 3
- Views: 2782
Re: Coleman furnace
Hi, Not sure which pressure switch you received, but the replacement switch does have a different p/n, but also has the two vacuum ports. Sorry for the wrong part and misinformation. For the ignitor, there is often more than one problem that arise at same time, sometimes tied together. In this case,...
- Tue Jan 25, 2011 4:55 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Evcon EB17B Serial#950531147
- Replies: 7
- Views: 3882
Re: Coleman Evcon EB17B Serial#950531147
Hi,
Could be several things. Need to check for voltage at blower motor and elements to find out exactly where the interruption in power is at.
Thanks,
Robert
Could be several things. Need to check for voltage at blower motor and elements to find out exactly where the interruption in power is at.
Thanks,
Robert
- Tue Jan 25, 2011 4:04 pm
- Forum: Coleman Service & Repair
- Topic: Coleman DGAT075BDD Four Flashing Lights
- Replies: 7
- Views: 3844
Re: Coleman DGAT075BDD Four Flashing Lights
Hi,
You're very welcome, happy to help.
Thanks,
Robert
You're very welcome, happy to help.
Thanks,
Robert