Search found 292 matches

by hvac1000
Thu Nov 22, 2007 7:58 pm
Forum: Coleman Service & Repair
Topic: Coleman heater gets stuck going off and on...
Replies: 3
Views: 2651

RE: Coleman heater gets stuck going off and on...

Sometimes the furnace seems to get stuck and it keeps going off and on, off and on

What is going off and on the blower or the burner?
by hvac1000
Thu Nov 22, 2007 7:56 pm
Forum: Coleman Service & Repair
Topic: Coleman EB17A electric furnace
Replies: 5
Views: 5232

RE: Coleman EB17A electric furnace

Sounds like a sequencer problem.
part number
3115-3571

OR fan relay 3110-3301
by hvac1000
Thu Nov 22, 2007 10:48 am
Forum: All Other HVAC Questions
Topic: Water Heater pilot
Replies: 6
Views: 3841

You might be better off letting a professional check out your water heater problem.
by hvac1000
Thu Nov 22, 2007 2:27 am
Forum: All Other HVAC Questions
Topic: Water Heater pilot
Replies: 6
Views: 3841

RE: Water Heater pilot

There is really no test for the pilot orifice it is perfectly clean or is partially restricted. You have to take it apart to check this. Combustion air is the air that is burnt by the gas flame in the water heater. it takes a lot of air to burn clean and with no problems. You will notice somewhere a...
by hvac1000
Thu Nov 22, 2007 1:34 am
Forum: All Other HVAC Questions
Topic: Water Heater pilot
Replies: 6
Views: 3841

If a downdraft from the vent going thru the roof is causing this problem something is wrong with the vent system. Has this just started? Your pilot orifice might be partially plugged causing a short or insufficient flame. Does your water heater have enough combustion air for it to burn well when lit...
by hvac1000
Thu Nov 22, 2007 1:30 am
Forum: Nordyne Service & Repair
Topic: CONVERT NORDYNE FURNACE FROM NATURAL GAS TO PROPANE
Replies: 4
Views: 7456

Yes it can be converted with a pilot and main orifice change, This is ONLY to be done by a trained professional HVAC person with knowlwdge of the furnace in your Mobile home.

This is not a do it yourself job.
by hvac1000
Wed Nov 21, 2007 2:06 pm
Forum: Nordyne Service & Repair
Topic: Intertherm Gas Furnace. Blower coming on intermittently
Replies: 8
Views: 10048

You would have to have one huge pilot to cause the blower to come on like in your description.

In fact I do not think you can get a pilot large enough to effect the blower control.

Have a great Thanksgiving.
by hvac1000
Wed Nov 21, 2007 9:35 am
Forum: Coleman Service & Repair
Topic: Coleman Red T DGAA070BDTA Igniter burnout
Replies: 4
Views: 4158

In all the many years in the HVAC biz I have never had a problem with ignitors like you have. ((they have a website at www.ignitersdirect.com and are warranted for 3 years)) Looks like you can send them back and get a free one under the warrenty at least. BTW there is a cure for what you are talking...
by hvac1000
Wed Nov 21, 2007 9:18 am
Forum: Service & Repair of Other Brands
Topic: No heat on one side.
Replies: 1
Views: 3567

RE: No heat on one side.

More than likely the jumper duct has come loose under your home.
by hvac1000
Wed Nov 21, 2007 9:07 am
Forum: Nordyne Service & Repair
Topic: Intertherm Gas Furnace. Blower coming on intermittently
Replies: 8
Views: 10048

RE: Intertherm Gas Furnace. Blower coming on intermittently

Sounds like the combination fan and limit control. NOTE: this control controls the operation of the fan depending upon how much heat is in the furnace. It turns the fan off or on depending upon the furnace temp. More than likely yours is out of calibration BUT I would check the following before orde...
by hvac1000
Wed Nov 21, 2007 8:45 am
Forum: Coleman Service & Repair
Topic: Coleman 3500a816 no fan no power out of transformer
Replies: 1
Views: 1960

Your part number is

621299 Transformer = 3400-384

order on this page (top right side)

http://www.mobilehomerepair.com/ColemanElec.html

Thank you and have a great Thanksgiving.
by hvac1000
Wed Nov 21, 2007 8:37 am
Forum: Coleman Service & Repair
Topic: Coleman Red T DGAA070BDTA Igniter burnout
Replies: 4
Views: 4158

RE: Coleman Red T DGAA070BDTA Igniter burnout

If you can find one of these that will fit your burner get one. They do last longer. http://www.white-rodgers.com/wrdhom/pdfs/sell_sheets/wr_7071_1_21D64_2_NitrideMod_SS.pdf Cross refrence http://www.white-rodgers.com/wrdhom/pdfs/instruction_sheets/0037-6299.pdf You might also check with Robert on t...
by hvac1000
Sun Nov 18, 2007 12:22 pm
Forum: Nordyne Service & Repair
Topic: Combustion blower motor on CMF 100-PO runs continuously
Replies: 4
Views: 4965

RE: Combustion blower motor on CMF 100-PO runs continuously

This is taken direct from Nordyne/Miller Note: Type 12S Series are time delay relays used as sequencers on electric heating products. (((12S includes the part number you were asking about 105144000 time delay relay for electric furnaces only. ))) The time delay you are talking about is for a electri...
by hvac1000
Thu Nov 15, 2007 3:21 pm
Forum: Coleman Service & Repair
Topic: Coleman Presidential Furnace
Replies: 3
Views: 2956

RE: Coleman Presidential Furnace

Usually the transformer makes that jind of noise. It is common.
by hvac1000
Thu Nov 15, 2007 6:45 am
Forum: Coleman Service & Repair
Topic: Colemman 7956-856 blower stays on
Replies: 6
Views: 3788

RE: Colemman 7956-856 blower stays on

Robert ??

What I am getting for this unit is a
6313-2281 blower relay

OR

a 7975-3281 fan and limit.

If the fan limit is tripped will the blower run all the time on this model?

I wounder if this is a 2 wire system?

I hate to give the wrong info.