Search found 292 matches

by hvac1000
Sat Dec 01, 2007 2:40 pm
Forum: Coleman Service & Repair
Topic: Coleman model 4084A656, with 40084-6601 gas conversion
Replies: 9
Views: 4813

RE: Coleman model 4084A656, with 40084-6601 gas conversion

I am not much on noise discriptions. Does the main blower run that blows air into the house?

if the burner you have has a flame sensor clean it with steel wool or sandpaper (the metal part).

report back
by hvac1000
Sat Dec 01, 2007 2:23 pm
Forum: Nordyne Service & Repair
Topic: Nordyne furnace will not stay lit
Replies: 9
Views: 7446

Check for a spider web or dirt behind the burner orifice.
by hvac1000
Sat Dec 01, 2007 2:22 pm
Forum: Nordyne Service & Repair
Topic: A-Coil from old furnace added to a new Miller Elec Furnace..
Replies: 4
Views: 5565

First they left the refrigerant line connections open to the air. BAD NEWS and furthermore they did not bother to tape them up. More bad news. Mobile home units are usually designed as a blow thru not a draw thru style. Tell them you want it exactly as listed on your agreement. You are paying for th...
by hvac1000
Sat Dec 01, 2007 2:13 pm
Forum: Coleman Service & Repair
Topic: Evcon DGAA070BDTB blower won't kick on
Replies: 5
Views: 3954

Does the burner run and does the furnace get hot? Is it just the blower than is not working?
by hvac1000
Sat Dec 01, 2007 2:12 pm
Forum: Coleman Service & Repair
Topic: Coleman model 4084A656, with 40084-6601 gas conversion
Replies: 9
Views: 4813

I recommend you contact a professional for any and all conversions. There is mort to it than orifice changes. You need special tools to be able to adjust gas pressure and make sure the system is safe.
by hvac1000
Fri Nov 30, 2007 9:24 pm
Forum: Nordyne Service & Repair
Topic: Intertherm Gas Furnace. Blower coming on intermittently
Replies: 8
Views: 10058

RE: Intertherm Gas Furnace. Blower coming on intermittently

The problem is residual heat. Usually there is enough differential in the control to stop this from happening.

Something would have to kick on the blowwer relay for it to be a problem.

Are you sure all the ducts are open and the filter and return air are not blocked in any way?
by hvac1000
Wed Nov 28, 2007 4:20 am
Forum: Nordyne Service & Repair
Topic: Miller furnace CMF-80 PG-DI, no voltage to t-stat
Replies: 1
Views: 2147

Check the low voltage transformer.
by hvac1000
Tue Nov 27, 2007 1:30 pm
Forum: Mobile Home Repair
Topic: Water in attic space
Replies: 3
Views: 2065

RE: Water in attic space

The unit will remove excess moisture in the entire home. This eventually and in short order will cause removal of the moisture in the attic space. The moisture in the attic space comes from within the home to start with unless you have a leak in the roof. No duct is required to be placed into the at...
by hvac1000
Tue Nov 27, 2007 1:35 am
Forum: Mobile Home Repair
Topic: Water in attic space
Replies: 3
Views: 2065

RE: Water in attic space

I use a electric dehumidifier running constantly. Run the hose on the adapter or remember to drain the catch bucket.
by hvac1000
Sat Nov 24, 2007 11:10 am
Forum: Coleman Service & Repair
Topic: Coleman 7956C856 Burner stays on, blower runs short bursts
Replies: 4
Views: 3038

I would just use a small wire to make sure the orifice is open. Many times I remove it to make sure there is not a spider web hidding on the back side.
by hvac1000
Sat Nov 24, 2007 6:30 am
Forum: Coleman Service & Repair
Topic: Coleman heater gets stuck going off and on...
Replies: 3
Views: 2665

If you can put the blower in a constant run position. You can do this by using a jumper on the control you replaced last year. This will take the control out of the circuit and eliminate the on and off if the control is the problem. If this corrects the situation then you know the control is defecti...
by hvac1000
Sat Nov 24, 2007 12:58 am
Forum: Nordyne Service & Repair
Topic: nordyne furnace problem!!!
Replies: 1
Views: 2275

Check for a obstruction in the vent/exhaust gas line.
by hvac1000
Sat Nov 24, 2007 12:57 am
Forum: Coleman Service & Repair
Topic: Coleman 7956C856 Burner stays on, blower runs short bursts
Replies: 4
Views: 3038

RE: Coleman 7956C856 Burner stays on, blower runs short burs

You may try cleaning the main orifice just in case it is partially plugged up causing a lack of flame size.

Other items like checking the gas pressure etc take special tools and knowledge. This is best left to a professional that know exactly what they are doing.
by hvac1000
Thu Nov 22, 2007 8:06 pm
Forum: Coleman Service & Repair
Topic: Coleman Presidential III - Filter?
Replies: 2
Views: 4401

There is usually a filter in the door of your unit. You do have to take the louvered door off to replace. The filter listed at the address below is washable. Check to make sure your filter bracket is still in the door or you will have to order one of them also. http://www.mobilehomerepair.com/Colema...
by hvac1000
Thu Nov 22, 2007 8:00 pm
Forum: Coleman Service & Repair
Topic: coleman model 767ob856
Replies: 2
Views: 2199

You best call for service. This is not normal and should be addresses ASAP. I cannot find your exact model number but I believe it is a gas furnace?