by Robert
Wed Jan 26, 2011 9:25 pm
Forum: Coleman Service & Repair
Topic: Coleman heater keeps shutting off
Replies: 8
Views: 4302

Re: Coleman heater keeps shutting off

Hi Craig, The top switch is a fan Switch. The bottom is a lower limit switch. Fan Switch # 7975 - 3281 can be seen and ordered here by paging down : http://www.aberdeenhomerepair.com/store/product/2412/F110-20F--fan-switch-7975-3281 IF you need or wish to get the lower limit, after adding fan switch...
by Robert
Wed Jan 26, 2011 8:03 pm
Forum: Coleman Service & Repair
Topic: Coleman heater keeps shutting off
Replies: 8
Views: 4302

Re: Coleman heater keeps shutting off

Hi Craig,

What is the complete furnace model number ? Is the limit that is tripping up next to or attached to the blower housing ?


Or is it about midway of the furnace ?




Thanks,
Robert
by Robert
Wed Jan 26, 2011 7:05 pm
Forum: Coleman Service & Repair
Topic: Coleman Evcon EB17B Serial#950531147
Replies: 7
Views: 3874

Re: Coleman Evcon EB17B Serial#950531147

Hi Zac,

Go to transformer and test Primary-Line side for 240vac across the two terminals.


Then go to other side, Secondary-Load side and test for 24vac.



Let me know what you get.



Thanks,
Robert
by Robert
Wed Jan 26, 2011 5:30 am
Forum: Coleman Service & Repair
Topic: Coleman EB15B intermittent auto fan problem
Replies: 13
Views: 24170

Re: Coleman EB15B intermittent auto fan problem

You're very welcome, happy to help.



Thanks,
Robert
by Robert
Wed Jan 26, 2011 4:11 am
Forum: Coleman Service & Repair
Topic: Coleman furnace
Replies: 3
Views: 2781

Re: Coleman furnace

HI, What I was saying is that the ignitor could have been going bad earlier, but the inducer motor problem/pressure switch problem would override it and diagnostic light would show that first. Once you corrected that and got it going again, the ignitor problem surfaced on diagnostic light. IF it get...
by Robert
Tue Jan 25, 2011 8:44 pm
Forum: Coleman Service & Repair
Topic: Coleman EB15B intermittent auto fan problem
Replies: 13
Views: 24170

Re: Coleman EB15B intermittent auto fan problem

Hi,

This website, online store and the aberdeenhomerepair.com store are all owned by Mark Bower.

I do contracted work for him on here and through emails.



Thanks,
Robert
by Robert
Tue Jan 25, 2011 7:39 pm
Forum: Coleman Service & Repair
Topic: Coleman EB15B intermittent auto fan problem
Replies: 13
Views: 24170

Re: Coleman EB15B intermittent auto fan problem

Hi,

The t-stat itself will often cause problems. Great ceiling fans, but not t-stats.


The sequencer test itself was all that was needed.


Thanks,
Robert
by Robert
Tue Jan 25, 2011 7:33 pm
Forum: All Other HVAC Questions
Topic: More Specific Ductless/Mini Split AC Question
Replies: 4
Views: 3154

Re: More Specific Ductless/Mini Split AC Question

Hi,

You're very welcome, we're happy to help.



Take care and best wishes,
Robert
by Robert
Tue Jan 25, 2011 7:29 pm
Forum: Service & Repair of Other Brands
Topic: Filter location for AGC100GAS
Replies: 1
Views: 15174

Re: Filter location for AGC100GAS

Hi,

Yes, it goes behind the upper louvered door.

Filter # 102957000

Filter Retainer # 302257000

Call Mark @ 605-229-2627 and see if he has those or can get them or a compatible replacement.



Thanks,
Robert
by Robert
Tue Jan 25, 2011 6:57 pm
Forum: Nordyne Service & Repair
Topic: Hey everyone....
Replies: 5
Views: 3862

Re: Hey everyone....

Hi,

Do you still need any help with this ?


Thanks,
Robert
by Robert
Tue Jan 25, 2011 6:46 pm
Forum: Nordyne Service & Repair
Topic: Nordyne Intertherm E2EB-020HB
Replies: 1
Views: 3216

Re: Nordyne Intertherm E2EB-020HB

Hi, Your furnace has two contactors and two relays that together control the elements and the blower motor . The circuits can run through them even though that one may not actually control the circuit or component. Without thorough electrical testing, hard to say which one may be at fault or if it's...
by Robert
Tue Jan 25, 2011 5:22 pm
Forum: Coleman Service & Repair
Topic: Coleman EB15B intermittent auto fan problem
Replies: 13
Views: 24170

Re: Coleman EB15B intermittent auto fan problem

Hi, Sequencer is definitely bad. Sequencer # 3115 - 3571 can be seen and ordered from here by paging down: http://www.aberdeenhomerepair.com/store/product/2311/3115-3571-sequencer I would suggest replacing the Hunter t-stat with a Honeywell. IF you choose to remain with the Hunter, leave it set to H...
by Robert
Tue Jan 25, 2011 5:05 pm
Forum: Coleman Service & Repair
Topic: Coleman furnace
Replies: 3
Views: 2781

Re: Coleman furnace

Hi, Not sure which pressure switch you received, but the replacement switch does have a different p/n, but also has the two vacuum ports. Sorry for the wrong part and misinformation. For the ignitor, there is often more than one problem that arise at same time, sometimes tied together. In this case,...
by Robert
Tue Jan 25, 2011 4:55 pm
Forum: Coleman Service & Repair
Topic: Coleman Evcon EB17B Serial#950531147
Replies: 7
Views: 3874

Re: Coleman Evcon EB17B Serial#950531147

Hi,

Could be several things. Need to check for voltage at blower motor and elements to find out exactly where the interruption in power is at.



Thanks,
Robert
by Robert
Tue Jan 25, 2011 4:04 pm
Forum: Coleman Service & Repair
Topic: Coleman DGAT075BDD Four Flashing Lights
Replies: 7
Views: 3833

Re: Coleman DGAT075BDD Four Flashing Lights

Hi,

You're very welcome, happy to help.



Thanks,
Robert