Search found 6413 matches
- Mon Jan 24, 2011 7:32 pm
- Forum: Nordyne Service & Repair
- Topic: limt tripping
- Replies: 1
- Views: 2299
Re: limt tripping
Hi, You cannot look at an a-coil and determine if it is clean or not. Need to test airflow across filter and across a-coil. Ensure you are getting proper cfm through the furnace and across the element coils. Also, those sequencers work on a timing pattern and you will not always have all elements on...
- Mon Jan 24, 2011 6:21 pm
- Forum: Coleman Service & Repair
- Topic: furnace ignitor not working all the time
- Replies: 1
- Views: 1387
Re: furnace ignitor not working all the time
Hi,
Test ignitor leads for 120vac with a call for heat whenever the ignitor should be energized.
Thanks,
Robert
Test ignitor leads for 120vac with a call for heat whenever the ignitor should be energized.
Thanks,
Robert
- Mon Jan 24, 2011 5:53 pm
- Forum: Coleman Service & Repair
- Topic: Coleman DGAT075BDD Four Flashing Lights
- Replies: 7
- Views: 3846
Re: Coleman DGAT075BDD Four Flashing Lights
Hi,
Manuals and wiring diagrams link :
http://www.hvacmanuals.com/
If you have any problems ordering or registering, call Mark @ 605-229-2627.
Thanks,
Robert
Manuals and wiring diagrams link :
http://www.hvacmanuals.com/
If you have any problems ordering or registering, call Mark @ 605-229-2627.
Thanks,
Robert
- Sat Jan 22, 2011 8:36 pm
- Forum: Nordyne Service & Repair
- Topic: Adding an Outside Compressor for AC; Put Return Where?
- Replies: 4
- Views: 2884
Re: Adding an Outside Compressor for AC; Put Return Where?
Hi, When it was installed, did it come set up for a/c ? Did it have two door panels ? Solid bottom door in front of furnace and a louvered upper door ? If so, the a-coil sit atop the furnace and the return air comes in through the upper louvered door. If not and you have an open top furnace with a f...
- Sat Jan 22, 2011 8:10 pm
- Forum: Coleman Service & Repair
- Topic: Coleman DGAA070BDTA control board?
- Replies: 10
- Views: 6557
Re: Coleman DGAA070BDTA control board?
Hi Dave,
You're very welcome, happy to help.
Take care and best wishes,
Robert
You're very welcome, happy to help.
Take care and best wishes,
Robert
- Sat Jan 22, 2011 5:13 pm
- Forum: Coleman Service & Repair
- Topic: Coleman DGAA070BDTA control board?
- Replies: 10
- Views: 6557
Re: Coleman DGAA070BDTA control board?
Hi,
Yes, red wire to SEC on board.
Thanks,
Robert
Yes, red wire to SEC on board.
Thanks,
Robert
- Sat Jan 22, 2011 3:58 pm
- Forum: Coleman Service & Repair
- Topic: Coleman DGAT075BDD Four Flashing Lights
- Replies: 7
- Views: 3846
Re: Coleman DGAT075BDD Four Flashing Lights
HI,
Four Flashes is a limit switch cycling. You will need to first determine which limit is kicking out and then determine why.
Make sure the filter, blower motor and wheel and a/c a-coil if you have a/c are all clean so as to not restrict airflow through furnace chamber.
Thanks,
Robert
Four Flashes is a limit switch cycling. You will need to first determine which limit is kicking out and then determine why.
Make sure the filter, blower motor and wheel and a/c a-coil if you have a/c are all clean so as to not restrict airflow through furnace chamber.
Thanks,
Robert
- Thu Jan 20, 2011 8:54 pm
- Forum: Coleman Service & Repair
- Topic: Intermitent Blower operation
- Replies: 1
- Views: 1348
Re: Intermitent Blower operation
Hi,
Make sure all wires are tight and not loose. If so, that is often due to a bad fan switch.
Fan Switch # 7975 - 3281 can be seen and ordered here by paging down :
http://www.aberdeenhomerepair.com/store ... -7975-3281
Thanks,
Robert
Make sure all wires are tight and not loose. If so, that is often due to a bad fan switch.
Fan Switch # 7975 - 3281 can be seen and ordered here by paging down :
http://www.aberdeenhomerepair.com/store ... -7975-3281
Thanks,
Robert
- Thu Jan 20, 2011 8:06 pm
- Forum: Coleman Service & Repair
- Topic: Coleman 3400-820
- Replies: 9
- Views: 5110
Re: Coleman 3400-820
Hi,
Get out the volt meter and it'll skeer them furnaces every time,LOL. You're right, can't test or repair what is not broken at the time.
Holler when she hiccups again.
Thanks,
Robert
Get out the volt meter and it'll skeer them furnaces every time,LOL. You're right, can't test or repair what is not broken at the time.
Holler when she hiccups again.
Thanks,
Robert
- Wed Jan 19, 2011 8:22 pm
- Forum: Nordyne Service & Repair
- Topic: Adding an Outside Compressor for AC; Put Return Where?
- Replies: 4
- Views: 2884
Re: Adding an Outside Compressor for AC; Put Return Where?
Hi,
What is furnace model number ?
Is your furnace a downflow with floor supply registers throughout the home ?
Thanks,
Robert
What is furnace model number ?
Is your furnace a downflow with floor supply registers throughout the home ?
Thanks,
Robert
- Wed Jan 19, 2011 8:19 pm
- Forum: Nordyne Service & Repair
- Topic: Blower works intermittently in auto.
- Replies: 1
- Views: 2110
Re: Blower works intermittently in auto.
Hi,
The blower motor and elements are controlled by sequencers.
Sequencer # 01 - 0842 can be seen and ordered here by paging down :
http://www.aberdeenhomerepair.com/store ... 8621678%29
Could be a bad sequencer or a bad motor.
Thanks,
Robert
The blower motor and elements are controlled by sequencers.
Sequencer # 01 - 0842 can be seen and ordered here by paging down :
http://www.aberdeenhomerepair.com/store ... 8621678%29
Could be a bad sequencer or a bad motor.
Thanks,
Robert
- Tue Jan 18, 2011 6:49 pm
- Forum: Coleman Service & Repair
- Topic: Coleman 3400-820
- Replies: 9
- Views: 5110
Re: Coleman 3400-820
Hi Jeremy,
IF you tested as stated with furnace not turning off at that time, it would lead to the problem.
Need to know what each and every test result is/was.
Thanks,
Robert
IF you tested as stated with furnace not turning off at that time, it would lead to the problem.
Need to know what each and every test result is/was.
Thanks,
Robert
- Tue Jan 18, 2011 2:34 am
- Forum: Coleman Service & Repair
- Topic: Coleman 3400-820
- Replies: 9
- Views: 5110
Re: Coleman 3400-820
Hi Jeremy,
Yes, wall thermostat (t-stat).
Thanks,
Robert
Yes, wall thermostat (t-stat).
Thanks,
Robert
- Tue Jan 18, 2011 12:17 am
- Forum: Coleman Service & Repair
- Topic: Coleman 3400-820
- Replies: 9
- Views: 5110
Re: Coleman 3400-820
Hi Jeremy, Look at left end of each element coil for a spade terminal on a white ceramic insulator. Take a volt meter and place one lead on the terminal and the other on an unpainted metal screw. Test for 120vac. Do this with thermostat turned OFF and furnace coils still energized as you stated. IF ...
- Mon Jan 17, 2011 11:59 pm
- Forum: Coleman Service & Repair
- Topic: Coleman DGAA070BDTA control board?
- Replies: 10
- Views: 6557
Re: Coleman DGAA070BDTA control board?
Hi Dave,
You're very welcome, happy to help. Thanks for ordering with us.
Take care and best wishes,
Robert
You're very welcome, happy to help. Thanks for ordering with us.
Take care and best wishes,
Robert