Hi,
Generally the flexible ductwork found here is what's recommended: http://www.aberdeenhomerepair.com/store ... 8/Ductwork
Mark
Search found 742 matches
- Wed Oct 12, 2011 11:00 am
- Forum: All Other HVAC Questions
- Topic: Crossover duct
- Replies: 5
- Views: 3557
- Wed Oct 12, 2011 10:56 am
- Forum: Coleman Service & Repair
- Topic: Coleman DGAA070BDTA Not lighting up
- Replies: 6
- Views: 5411
Re: Coleman DGAA070BDTA Not lighting up
Hi, If the problem is worn-out parts (and not a plugged airway or cracked heat exchanger), then there's probably 1 of 2 parts that you need. When you first turn the thermostat on, you should hear the booster motor running. If it's not running, it may have taken on some moisture over the summer and g...
- Wed Oct 12, 2011 10:50 am
- Forum: Coleman Service & Repair
- Topic: Coleman EB10B Filter
- Replies: 1
- Views: 2011
Re: Coleman EB10B Filter
Hi,
Should be a 16x20 filter on top.
Mark
Should be a 16x20 filter on top.
Mark
- Tue Oct 11, 2011 4:21 pm
- Forum: All Other HVAC Questions
- Topic: Furnace Replacement
- Replies: 1
- Views: 2249
Re: Furnace Replacement
Hi, Compared to a gas unit, electric furnaces are fairly easy to replace. Like you said, you basically shut off the power, remove the power wires and thermostat wires, disconnect from ductwork and take out. Put in the new following the same steps in reverse. If you have air conditioning attached to ...
- Tue Oct 11, 2011 4:18 pm
- Forum: Service & Repair of Other Brands
- Topic: intertherm ezeb-15hb buzz
- Replies: 1
- Views: 16759
Re: intertherm ezeb-15hb buzz
Sure it's not a transformer or contactor that's buzzing?
Mark
Mark
- Mon Oct 10, 2011 11:13 pm
- Forum: Coleman Service & Repair
- Topic: HELP PLEASE !! COLEMAN DGAA708BDTA
- Replies: 3
- Views: 3099
Re: HELP PLEASE !! COLEMAN DGAA708BDTA
With the power off, removing the black box and nudging it with a screwdriver may be enough to get it unstuck and running. If you are having to do that every year, you are getting moisture in there during the summer and its causing some rust. Eventually it'll need to be replaced. To replace you need ...
- Mon Oct 10, 2011 11:11 pm
- Forum: Coleman Service & Repair
- Topic: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)
- Replies: 4
- Views: 3658
Re: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)
Hi, You can test the booster assembly the same way. Run power directly to the 2 wires and see if it runs. Yes, you need to remove or loosen all that stuff below so the draft booster can slide down and out. The little black box is included.
Mark
Mark
- Sun Oct 09, 2011 8:58 pm
- Forum: Coleman Service & Repair
- Topic: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)
- Replies: 4
- Views: 3658
Re: Help My 86-yr. Old Mom Get Heat! (Coleman DGAH056BBSB)
If the booster motor did not turn on instantly, replace it. If it's not running, it can't trip the pressure switch which is causing the fault code on the control board. You can see and order the booster assembly for your furnace here: http://www.aberdeenhomerepair.com/store/product/2339/373-19801-82...
- Sat Oct 08, 2011 10:15 pm
- Forum: Nordyne Service & Repair
- Topic: Blower Questions E1EH1-015A
- Replies: 1
- Views: 2609
Re: Blower Questions E1EH1-015A
Remove the black wire and put the red wire in its place.
Mark
Mark
- Sat Oct 08, 2011 10:12 pm
- Forum: Nordyne Service & Repair
- Topic: Major problems with E1EH1-015A
- Replies: 4
- Views: 4016
Re: Major problems with E1EH1-015A
Hi,
Sorry about the slow response. Did you get things figured out?
Mark
Sorry about the slow response. Did you get things figured out?
Mark
- Sat Oct 08, 2011 10:10 pm
- Forum: Coleman Service & Repair
- Topic: furnance not igniting
- Replies: 1
- Views: 2195
Re: furnance not igniting
If you get a brief flame, try replacing or cleaning the flame sensor with a light touch of steel wool. Otherwise need to know more details.
Mark
Mark
- Sat Oct 08, 2011 10:08 pm
- Forum: Coleman Service & Repair
- Topic: coleman/evcon DGAT 070BDC , no power to the combustion motor
- Replies: 3
- Views: 3604
Re: coleman/evcon DGAT 070BDC , no power to the combustion m
Hooking wires together on the Centrifugal switch won't get the booster motor going. Spinning the motor may work the first couple seasons, but eventually the rust will take over and it's time for a new booster motor. Here you can see the booster motor for your furnace: http://www.aberdeenhomerepair.c...
- Sat Oct 08, 2011 9:59 pm
- Forum: Coleman Service & Repair
- Topic: HELP PLEASE !! COLEMAN DGAA708BDTA
- Replies: 3
- Views: 3099
Re: HELP PLEASE !! COLEMAN DGAA708BDTA
Sounds like the booster assembly finally died. Part # 373-19801-821. Can be seen here: http://www.aberdeenhomerepair.com/store ... oster-assy
- Sat Oct 08, 2011 9:55 pm
- Forum: Coleman Service & Repair
- Topic: DGAT056BDD Ignition Problem
- Replies: 1
- Views: 3817
Re: DGAT056BDD Ignition Problem
I would start by cleaning the flame sensor. If that doesn't solve the problem, then take a look at the board.
Mark
Mark
- Sat Oct 08, 2011 9:53 pm
- Forum: Coleman Service & Repair
- Topic: Booster Motor
- Replies: 2
- Views: 2620
Re: Booster Motor
Glad you got it figured out.
Mark
Mark