Hi,
Most likely a sequencer problem.
Sequencer # 901076 can be seen and ordered from here by paging down to it :
http://www.aberdeenhomerepair.com/store ... er-4-stage
Thanks,
Robert
Search found 6413 matches
- Thu Feb 03, 2011 5:59 pm
- Forum: Nordyne Service & Repair
- Topic: Intertherm FEH-023HA blows cold air
- Replies: 1
- Views: 2916
- Thu Feb 03, 2011 4:51 pm
- Forum: Coleman Service & Repair
- Topic: coleman7975-856 wont fire
- Replies: 1
- Views: 1488
Re: coleman7975-856 wont fire
Hi,
Inspect the burner tube and burner orifice/spud for clogs/blockages (spider-web-bugs).
IF all clear, will need an hvac tech who knows his trade, the last one does/did not qualify.
Thanks,
Robert
Inspect the burner tube and burner orifice/spud for clogs/blockages (spider-web-bugs).
IF all clear, will need an hvac tech who knows his trade, the last one does/did not qualify.
Thanks,
Robert
- Wed Feb 02, 2011 4:21 pm
- Forum: Coleman Service & Repair
- Topic: Coleman 7655-856
- Replies: 1
- Views: 2210
Re: Coleman 7655-856
Did you check the gas valve for 24vac ? Check the burner tube and burner orifice for clogs (spider-web-bugs).
Thanks,
Robert
Thanks,
Robert
- Tue Feb 01, 2011 6:41 pm
- Forum: Coleman Service & Repair
- Topic: help
- Replies: 1
- Views: 1317
Re: help
Hi, Go here for steps to troubleshoot your Blend Air System: http://www.mobilehomerepair.com/hvac/ArticleBlendAir.html You can disconnect it for now and work toward finding the problem and repairing when it is warmer. It is a separate system from your furnace and is not needed in order to operate th...
- Tue Feb 01, 2011 6:26 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne RC92+ Gas furnace
- Replies: 5
- Views: 4008
Re: Nordyne RC92+ Gas furnace
Hi, I deleted the other extremely long post because I do not have time unfortunately to read all that and do not need the sequences of your furnace operation spelled out for me. It also may have some info that is not allowed on here for the viewing public. Here is a link for my troubleshooting fee i...
- Tue Feb 01, 2011 5:26 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne RC92+ Gas furnace
- Replies: 5
- Views: 4008
Re: Nordyne RC92+ Gas furnace
Hi,
It may work, but the reason it was not getting voltage could be due to a safety issue interrupting the power to it for safety.
IF that was/is the case, doing what you did bypassed that and could create a dangerous
situation.
Thanks,
Robert
It may work, but the reason it was not getting voltage could be due to a safety issue interrupting the power to it for safety.
IF that was/is the case, doing what you did bypassed that and could create a dangerous
situation.
Thanks,
Robert
- Tue Feb 01, 2011 5:23 pm
- Forum: Nordyne Service & Repair
- Topic: This may sound like a dumb question....
- Replies: 1
- Views: 2193
Re: This may sound like a dumb question....
Hi, What you described could be the sequencers or the limit switches. Only way to know would be to test them when it is happening. Anytime your furnace is not functioning properly, there is a risk of an electrical mishap causing a fire IF you continue to operate the furnace. I would only replace wha...
- Tue Feb 01, 2011 5:14 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne RC92+ Gas furnace
- Replies: 5
- Views: 4008
Re: Nordyne RC92+ Gas furnace
What is the furnace model number ? The gas valve not working may be to a safety issue, jumping it could prove dangerous and is not advised.
Thanks,
Robert
Thanks,
Robert
- Tue Feb 01, 2011 4:18 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne E2EB-015HA only gets warm
- Replies: 9
- Views: 7808
Re: Nordyne E2EB-015HA only gets warm
Hi Terri, Ok, you've been reading some in the forums it appears. Meter set to read above 240VAC, one meter lead on far right and other lead on far left coil terminals on white ceramic insulators. WITH a call for heat after 30-45 secs., you should read 240VAC across them. IF you do not, send me an em...
- Tue Feb 01, 2011 4:12 pm
- Forum: Coleman Service & Repair
- Topic: Evcon EB15B not heating properly
- Replies: 5
- Views: 2774
Re: Evcon EB15B not heating properly
Hi Barry,
Keep me posted if you need anything else.
Thanks,
Robert
Keep me posted if you need anything else.
Thanks,
Robert
- Tue Feb 01, 2011 4:11 pm
- Forum: Coleman Service & Repair
- Topic: DGAT070BDD Heater
- Replies: 4
- Views: 2552
Re: DGAT070BDD Heater
Hi Rob, That was the next thing I was going to ask IF the flame sensor cleaning did not help. ALL Coleman furnaces that fell under the recall program needed to be inspected and repaired if there was a problem. You could have issues with your heat exchanger. IF they do not find anything wrong or cann...
- Tue Feb 01, 2011 12:25 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne E2EB-015HA only gets warm
- Replies: 9
- Views: 7808
Re: Nordyne E2EB-015HA only gets warm
Hi Terri,
You will need to find someone with experience in using it as this is high voltage and too dangerous for a first time DIY attempt at it.
Thanks,
Robert
You will need to find someone with experience in using it as this is high voltage and too dangerous for a first time DIY attempt at it.
Thanks,
Robert
- Mon Jan 31, 2011 9:55 pm
- Forum: Coleman Service & Repair
- Topic: DGAT070BDD Heater
- Replies: 4
- Views: 2552
Re: DGAT070BDD Heater
Hi Rob,
Pull the remote flame sensor and clean the rod with steel wool. Do not touch it with your hands and be careful not to damage the ceramic shroud.
Thanks,
Robert
Pull the remote flame sensor and clean the rod with steel wool. Do not touch it with your hands and be careful not to damage the ceramic shroud.
Thanks,
Robert
- Mon Jan 31, 2011 9:45 pm
- Forum: Coleman Service & Repair
- Topic: eb23b
- Replies: 1
- Views: 1300
Re: eb23b
Hi Jim, For the heating elements to become energized, one of two things must occur. Either there is power getting through on the sequencer side due to a short or stuck sequencer contact. Or, part of the element coil has fallen down and is touching the frame or wall of furnace creating a pathway back...
- Mon Jan 31, 2011 9:10 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne E2EB-015HA only gets warm
- Replies: 9
- Views: 7808
Re: Nordyne E2EB-015HA only gets warm
Hi Terri,
Do you have a volt meter or can you get one and do some tests or have a neighbor/friend that can do some tests ?
Thanks,
Robert
Do you have a volt meter or can you get one and do some tests or have a neighbor/friend that can do some tests ?
Thanks,
Robert