Re: 3400-384 transformer replacement

Hi, No that is not the correct transformer. You can use any transformer that is 120 and 24 volt. They also make a transformer that is universal it can do 230 and 120 you just need to use the correct leads. You can pick this up at any part store. here is a link for a transformer that will work for yo...
by Bill
Mon Sep 19, 2011 9:48 pm
Forum: Coleman Service & Repair
Topic: Need help with DGAA056BDTA combustion blower motor
Replies: 2
Views: 3162

Re: Need help with DGAA056BDTA combustion blower motor

Hi
Sounds like you got it all figured out :) I hope that your furnace run good for you the rest of the heating season.
Thanks for using the forum
Bill
by Bill
Mon Sep 19, 2011 9:44 pm
Forum: Nordyne Service & Repair
Topic: Wiring harness for a Nordyne FEBB-012HA
Replies: 1
Views: 2753

Re: Wiring harness for a Nordyne FEBB-012HA

Hi Dave, I can't find the part number for a wiring harness for you. But what i did come up with is this http://hvacpartstore.com/nordynewire.html They should have what you are looking for. You can give them a call and I know that Mark and the crew will help you out. Sorry i was not able to get you t...
by Bill
Tue Sep 13, 2011 7:58 pm
Forum: Coleman Service & Repair
Topic: EVCON DGAT070BDC WIRE QUESTION
Replies: 2
Views: 2407

Re: EVCON DGAT070BDC WIRE QUESTION

Hi Not sure if you pulled all the wires off the thermostat or if you just found some extra wires. I would like to start with the Thermostat. On your stat you have R, W, G, and Y terminal. From what I can see on your model the R terminal should go to the red wire on the furnace. The W terminal should...
by Bill
Mon Sep 12, 2011 8:47 pm
Forum: Nordyne Service & Repair
Topic: Nordyne-Intertherm furnace MMHB-070ABHR-06 not lighting
Replies: 2
Views: 7575

Re: Nordyne-Intertherm furnace MMHB-070ABHR-06 not lighting

Hi and Welcome, I am not able to find a code light manual for your furnace. So i was wondering if you can look and see if anywhere on your furnace or furnace doors that there is a trouble code chart. If not then at what point does your furnace begin to fail. Here is a link on the basic operation of ...
by Bill
Mon Sep 12, 2011 8:35 pm
Forum: Coleman Service & Repair
Topic: Coleman model BRCQ0361BD
Replies: 1
Views: 6623

Re: Coleman model BRCQ0361BD

HI, Well i found the replacement drain pan. Here is a link for that. http://www.aberdeenhomerepair.com/store/product/2356/6324-5101-a-coil-drip-pan But if you call the crew over at Aberdeen home repair they will be able to tell you if you can get the correct piston for your coil. Or if you just have...
by Bill
Mon Sep 12, 2011 8:07 pm
Forum: Nordyne Service & Repair
Topic: Cleaning Intertherm unit floor ducts
Replies: 11
Views: 41888

Re: Cleaning Intertherm unit floor ducts

Hi Dave,
Sounds like you are on the right path. One thing to remember is that once you get your coil nice and clean is to make sure your air filter stays clean. That way you wont have to clean your coil again.
Thanks and hope this helps.
Bill
by Bill
Thu Sep 08, 2011 5:44 pm
Forum: Coleman Service & Repair
Topic: Coleman DGAA070BDTA pressure switch
Replies: 5
Views: 9293

Re: Coleman DGAA070BDTA pressure switch

HI,
http://www.aberdeenhomerepair.com/store ... oster-assy
is this the same booster that you have? and if so look at the cost difference
Thanks
Bill
by Bill
Thu Sep 08, 2011 5:39 pm
Forum: Coleman Service & Repair
Topic: Evcon DGAT070BDC wont turn on at all on heat!!
Replies: 3
Views: 3005

Re: Evcon DGAT070BDC wont turn on at all on heat!!

Hi again, The first place we need to look is the booster relay. Here is a link on how to check to see if your relay is good. http://www.youtube.com/user/pexring#p/u/0/Mci7gysJtI4 If you find this to be bad then here is where you can get a new one. http://www.hvacpartstore.com/2405.html I dont think ...
by Bill
Wed Sep 07, 2011 7:31 pm
Forum: Coleman Service & Repair
Topic: Evcon DGAT070BDC wont turn on at all on heat!!
Replies: 3
Views: 3005

Re: Evcon DGAT070BDC wont turn on at all on heat!!

Hi and welcome First I am going to give you a link on how a furnace works http://www.youtube.com/watch?v=dO5_wuCWFqA After watching the video can you tell me at what point does your furnace stop working? For example does your flue booster fan come on but the gas valve does not. If you can tell what ...
by Bill
Wed Sep 07, 2011 5:06 pm
Forum: Coleman Service & Repair
Topic: Coleman DGAA070BDTA pressure switch
Replies: 5
Views: 9293

Re: Coleman DGAA070BDTA pressure switch

Hi and welcome The first thing that comes to mind when you say that you have to replace your combustion air switch every year is that you have a bigger problem than a bad switch. The job of the switch is to make sure that your flue gases are going out the house. If your switch does not make it could...
by Bill
Wed Sep 07, 2011 4:44 pm
Forum: Coleman Service & Repair
Topic: DGAT blower goes off/on 7 times
Replies: 4
Views: 2917

Re: DGAT blower goes off/on 7 times

Hi
Just wondering if you have tried to change the run capacitor on the fan?
Thanks
Bill
by Bill
Mon Sep 05, 2011 5:13 pm
Forum: Nordyne Service & Repair
Topic: Cleaning Intertherm unit floor ducts
Replies: 11
Views: 41888

Re: Cleaning Intertherm unit floor ducts

Hi, Dave Here are a couple of web sites that will help you out with cleaning your coil http://homerepair.about.com/od/termsaf/g/fin_comb.html That is for you coil fin's will help to clean you don't want to use a wire brush it might do more harm than good. http://www.hvacpartstore.com/1917.html That ...
by Bill
Sat Sep 03, 2011 8:04 am
Forum: All Other HVAC Questions
Topic: Evcon Presidential Recall?
Replies: 2
Views: 3108

Re: Evcon Presidential Recall?

Hi Ed and welcome, Here is what I was able to find out for ya http://www.cpsc.gov/cpscpub/prerel/prhtml05/05047.html use this link to read about the recall. It does not look like the furnace you listed is on the recall. The recall was sometime ago, I don't know if you have heard of a new recall. I h...
by Bill
Thu Sep 01, 2011 6:53 pm
Forum: Coleman Service & Repair
Topic: DGAT blower goes off/on 7 times
Replies: 4
Views: 2917

Re: DGAT blower goes off/on 7 times

Hi and welcome
If you could please list your whole model number i will be able to look up your furnace and help out more with your problem.
Thanks
Bill