Search found 3 matches
- Tue Feb 01, 2011 5:31 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne RC92+ Gas furnace
- Replies: 5
- Views: 4066
Re: Nordyne RC92+ Gas furnace
It almost acts as if the relay on the board for the gas valve gets a quick click but does not stay engaged. I get one quick shot of power to the gv but then it all resets. I was reading another post from a guys with the same problem and flash codes. It didn't say wether he solved it or not.
- Tue Feb 01, 2011 5:20 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne RC92+ Gas furnace
- Replies: 5
- Views: 4066
Re: Nordyne RC92+ Gas furnace
The model is KG6RC-100C-16B. I checked it again at lunch time and still the same process happening. I jumped the valave to see if it would function with voltage and it does.
- Tue Feb 01, 2011 7:42 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne RC92+ Gas furnace
- Replies: 5
- Views: 4066
Nordyne RC92+ Gas furnace
I am having an issue with this furnace. Intermittently it will not light. I get the first 2 stages, inducer, then ignitor. When it goes to open the gas valve, the valve just clicks, and the system resets itself. I am getting three blinks on the panel. I ohmd the vac valve and it is function when vac...