Search found 5 matches
- Sat Jan 08, 2011 1:23 am
- Forum: Nordyne Service & Repair
- Topic: Weak flame, melted wires
- Replies: 8
- Views: 6857
Re: Weak flame, melted wires
Hi Robert, Sorry this took so long to get back. I took it apart again and the shrink wrap insulation was charred. Spud was clear. Had a different HVAC tech come to check it out yesterday. He installed the correct igniter, with the flame sensor in it and all is working correctly. Thanks for your help...
- Mon Jan 03, 2011 10:10 am
- Forum: Nordyne Service & Repair
- Topic: Weak flame, melted wires
- Replies: 8
- Views: 6857
Re: Weak flame, melted wires
Hi Robert, Yesterday, I put shrink tube on the exposed wires and put the furnace back together. Ran it once and it shut itself off after about 10 minutes. This morning I tried it again, and it has ran for about three cycles (normal thermostat controlled) without incident.....except for the blinking ...
- Sun Jan 02, 2011 9:52 pm
- Forum: Nordyne Service & Repair
- Topic: Weak flame, melted wires
- Replies: 8
- Views: 6857
Re: Weak flame, melted wires
I think I have found the part number I need.....903110A.
Thanks,
Dennis
Thanks,
Dennis
- Sun Jan 02, 2011 2:11 pm
- Forum: Nordyne Service & Repair
- Topic: Weak flame, melted wires
- Replies: 8
- Views: 6857
Re: Weak flame, melted wires
Hi Robert, I did a visual check of the orifice. Looks clean. Should I remove or blow it out? Voltage measures 120V, after the 45 sec delay. I see that the web site has three coil type ignitors, but I don't know which one I need. The Tech took my old one with him. Could you help out with the correct ...
- Sat Jan 01, 2011 5:01 pm
- Forum: Nordyne Service & Repair
- Topic: Weak flame, melted wires
- Replies: 8
- Views: 6857
Weak flame, melted wires
You fellas have a great web site and are preforming a wonderful service. Thanks in advance. Year 2000 Nordyne M1MB 090A BW propane conversion Ser # M1M 000402954 Two weeks ago, this heater quit with four red flashes on the Control Module status display(lockout due to failed ignition). I had an HVAC ...