by aamirghanchi
Mon Dec 17, 2012 11:25 am
Forum: Nordyne Service & Repair
Topic: Sequencer wiring
Replies: 5
Views: 7676

Re: Sequencer wiring

It was the 3 Amp fuse. Duh!
by aamirghanchi
Mon Dec 17, 2012 9:57 am
Forum: Nordyne Service & Repair
Topic: Sequencer wiring
Replies: 5
Views: 7676

Nordyne Not running after working for sometime with new sqnc

Everything was working last time, but now when I clipped the wires togetehr at M2 and tucked everything in and put back the covering, heating is not running at all either at Tstat set to Auto or Fan ON. Even the fan is not running. I am sure I didn't disconnect anything. All the wires are in their p...
by aamirghanchi
Sun Dec 16, 2012 6:55 pm
Forum: Nordyne Service & Repair
Topic: Sequencer wiring
Replies: 5
Views: 7676

Re: Sequencer wiring

No luck. Not in Radioshack or any of the retail auto stores. I finally bind the two terminals together with a wire and inserted one of them to the the M4 blade. This was my long term solutions for it.
by aamirghanchi
Sun Dec 16, 2012 12:27 pm
Forum: Nordyne Service & Repair
Topic: Sequencer wiring
Replies: 5
Views: 7676

Re: Sequencer wiring

Thanks Dale! I was not sure if such a thing "piggyback terminal" exists. I looked up all over the web. Thanks again. I will check at Radioshack.
by aamirghanchi
Tue Dec 11, 2012 7:19 pm
Forum: Nordyne Service & Repair
Topic: Sequencer wiring
Replies: 5
Views: 7676

Sequencer wiring

Hi, I am trying to replace the sequencer on Nordyne E2B-023HA electric furnace. But the new sequencer (01-0843) is a bit different when it comes to the M4 conection. ON the original sequencer M4 point/blade was such that one of the black wire coming from the breaker and the other black wire coming f...
by aamirghanchi
Tue Dec 11, 2012 12:05 am
Forum: Nordyne Service & Repair
Topic: Heating and blower will not come on all the time
Replies: 3
Views: 4998

Re: Heating and blower will not come on all the time

Hi, I am back after 2 and a half years and all wiser :) and am trying to replace the sequencer after all. But the new sequencer (01-0843) is a bit different when it comes to the M4 conection. ON the original sequencer M4 point/blade was such that one of the black wire coming from the breaker and the...
by aamirghanchi
Mon Mar 12, 2012 12:09 am
Forum: Nordyne Service & Repair
Topic: Heating and blower will not come on all the time
Replies: 3
Views: 4998

Re: Heating and blower will not come on all the time

Thanks Dale.

I will give it a try. I even dont know where the sequencer is, but I will poke around :)

Thanks again.
by aamirghanchi
Sat Mar 10, 2012 3:47 pm
Forum: Nordyne Service & Repair
Topic: Heating and blower will not come on all the time
Replies: 3
Views: 4998

Heating and blower will not come on all the time

I have Nordyne E2EB-023HA electric furnace. The heating and blower will not come on all the time. Its very random. I have replaced the thermostat with a new one, but the problem persists. It comes on when I flip the brakers off and on at the braker panel, but then after few heating cycles will not c...
by aamirghanchi
Sat Dec 11, 2010 6:05 pm
Forum: Off Topic Discussions
Topic: hoot aerobic septic system question
Replies: 1
Views: 3317

hoot aerobic septic system question

Hi. We have a hoot aerobic septic system. The system alert red light is flashing indicating that the water level is high enough. I remember that once a repair guy showed a complex step of running the pump manually by turning some switches on and off, so that the system does not have to wait till nig...
by aamirghanchi
Tue Aug 03, 2010 9:12 am
Forum: Nordyne Service & Repair
Topic: Cover for the A-Grill
Replies: 7
Views: 3213

Re: Cover for the A-Grill

Thanks so much for providing this service!
God bless.
by aamirghanchi
Mon Aug 02, 2010 6:09 pm
Forum: Nordyne Service & Repair
Topic: Cover for the A-Grill
Replies: 7
Views: 3213

Re: Cover for the A-Grill

Well... there is a furnace closet door with slots, if thats what you meant by "louvered door panel". The door shuts the whole closet. There is nothing to specifically cover the evaporator grill. The blower is covered though through a detachable snap-in door. Sorry for my ignorance of the t...
by aamirghanchi
Mon Aug 02, 2010 4:50 pm
Forum: Nordyne Service & Repair
Topic: Cover for the A-Grill
Replies: 7
Views: 3213

Re: Cover for the A-Grill

Hello Robert. Sorry for the late reply. If the picture goes through right, as you can see the evaporator coils is all exposed. Is this normal? I have not seen this in the earlier house we were living in. There is also a plastic flexible duct hanging from the closet ceiling. Probably the previous own...
by aamirghanchi
Mon Jul 19, 2010 6:50 pm
Forum: Mobile Home Repair
Topic: sealant / paint to ward off smell/out-gasing
Replies: 7
Views: 6190

Re: sealant / paint to ward off smell/out-gasing

Thanks JD. Thats a good lead. If you know of any place I can get Kilz primer at reasonable rates then please do let me know.

Thanks again.
by aamirghanchi
Mon Jul 19, 2010 4:24 pm
Forum: Nordyne Service & Repair
Topic: Cover for the A-Grill
Replies: 7
Views: 3213

Cover for the A-Grill

Hi.

For the double-wide I recently bought, the evaporator grill of my intertherm is exposed and is covered with all kinds of dust (rust?). Where can I get the cover for it? Are there any salvage yards or junk yards like they have for automobiles. I am outside Austin, TX.

Thanks
by aamirghanchi
Mon Jul 19, 2010 3:24 pm
Forum: Mobile Home Repair
Topic: sealant / paint to ward off smell/out-gasing
Replies: 7
Views: 6190

sealant / paint to ward off smell/out-gasing

Hi. I bought this 10 year old double wide in Texas. There is a lingering smell that gives you a headache for the first few times. I am convinced that its coming off of the walls and ceiling because of the material they have used when building it. Are there any paints /sealants available out there th...