Search found 22 matches
- Thu Jul 13, 2017 9:48 am
- Forum: Coleman Service & Repair
- Topic: DGAT Series furnace air-conditioning issue
- Replies: 0
- Views: 60887
DGAT Series furnace air-conditioning issue
Last year it was find the leak which was I did everything half ass when the place was built so no one secured the drip line into the line running outside so it popped out and was leaking in the basement ceiling. After cutting half the insulation out.. I secured it. This year I have another leak. Wat...
- Thu Jun 02, 2016 7:58 pm
- Forum: Coleman Service & Repair
- Topic: coleman furnace replacement 77,00 for 56,000 btu
- Replies: 1
- Views: 26153
Re: coleman furnace replacement 77,00 for 56,000 btu
At a bare minimum, you can use a figure of 20 BTUs per hour per square foot and multiply this by the total square footage to be heated or cooled, but this does not take into account climate, the amount of insulation you have, or the way you live. So 20 X 840 = 16,800. Even at 30 BTU per square foot ...
- Sat Dec 19, 2015 10:23 pm
- Forum: Coleman Service & Repair
- Topic: blower doesn't start error code
- Replies: 1
- Views: 23007
Re: blower doesn't start error code
http://www.searspartsdirect.com/partsdirect/user-manuals/UGAE075BUG-Coleman-Parts-Furnace-Parts-manual Download the service manual, and don't lose it, these are a bitch to find free. The blink code is usually the part that failed, in this case Tube, Pressure 15". http://postrv.com/HVAC/Gas%20Fu...
- Sun Nov 29, 2015 1:58 pm
- Forum: Mobile Home Repair
- Topic: 1998 Fairmont home
- Replies: 1
- Views: 2449
1998 Fairmont home
Looking for the plastic inserts that have the springs in it for the cabinet doors. The plastic piece is 3/4" long by 1/4" wide the spring is 3/8" long 1/8" wide.
- Tue Sep 08, 2015 8:09 pm
- Forum: Coleman Service & Repair
- Topic: Suction on blower access door
- Replies: 2
- Views: 21673
Re: Suction on blower access door
https://www.questargas.com/brochures/59050_Furnace%20and%20Safety%20Handbook.pdf This pops out at you right off the bat........ It is very important to make sure the blower compartment door is securely in place whenever your furnace is operating to ensure that these processes remain separate. Operat...
- Sun Sep 06, 2015 7:45 am
- Forum: Mobile Home Repair
- Topic: Fusan ASSE 1019A Outside faucet
- Replies: 2
- Views: 30752
Re: Fusan ASSE 1019A Outside faucet
http://www.homedepot.com/s/outside%20sillcock?NCNI-5
I said screw it, went this route. Now if it ever breaks again at least I can get parts with out being bent over. At $19.95 shipping and $7 for the repair kit that would be penny smart dollar foolish.
I said screw it, went this route. Now if it ever breaks again at least I can get parts with out being bent over. At $19.95 shipping and $7 for the repair kit that would be penny smart dollar foolish.
- Thu Aug 13, 2015 3:43 pm
- Forum: Mobile Home Repair
- Topic: Fusan ASSE 1019A Outside faucet
- Replies: 2
- Views: 30752
Fusan ASSE 1019A Outside faucet
It's a anti-siphon style the vacuum breaker blew out. Nothing out there seems to fit, too big for replacing the innards and cap. I can get a replacement, from china but with the kit and shipping and handling almost $27. I can buy and replace the whole fixture with tail pipe for about half that and n...
- Fri May 29, 2015 2:47 pm
- Forum: Mobile Home Repair
- Topic: Furnace dampers
- Replies: 0
- Views: 7367
Furnace dampers
I know the damper needs to be open in the winter to the windows don't freeze up, but should it be open in the summer when the air is on? Any benefits of leaving it open or turning it off to keep it closed.
- Wed Jan 21, 2015 10:13 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Evcon...Model #DGATO7OBDC...Relay Issue!
- Replies: 3
- Views: 13751
Re: Coleman Evcon...Model #DGATO7OBDC...Relay Issue!
OE relay #134-20103-301D is a (RELAY COIL 24V 50/60HZ 5 BLADE) Or (5 Prong Relay 134-20103-301D 14 FLA 84LRA 125 VAC 7FLA 42LRA 277 VAC COIL 24 V 50/60HZ 25A RES 277VAC). Same as #7945-3771. http://www.amazon.com/FURNACE-ONETRIP-FUNCTIONAL-REPLACEMENT-S1-7975-3771/dp/B009UDBYIU OneTrip PartsĀ® Two Ye...
- Mon Jan 19, 2015 10:03 pm
- Forum: Coleman Service & Repair
- Topic: Coleman Evcon...Model #DGATO7OBDC...Relay Issue!
- Replies: 3
- Views: 13751
Re: Coleman Evcon...Model #DGATO7OBDC...Relay Issue!
http://mobilehomerepair.com/phpbb/viewtopic.php?f=1&t=10746 Same relay I fought with. The terminals should be labeled 1/2/3/4 ect I just pulled terminal by terminal and matched the number to the color. It ended up the relay wasn't the problem so I put the old one back in. http://www.google.com/u...
- Mon Dec 01, 2014 9:59 pm
- Forum: Coleman Service & Repair
- Topic: Pilot going out
- Replies: 11
- Views: 19169
Re: Pilot going out
Follow the wires, they usually go to one main box. I looked at the pictures and don't see one.
- Sun Nov 30, 2014 10:07 pm
- Forum: Coleman Service & Repair
- Topic: Pilot going out
- Replies: 11
- Views: 19169
Re: Pilot going out
It has to have one. Usually in an enclosure mounted to the furnace cabinet.digifoss wrote:It's an older presidential. If it has a control board I haven't seen one. where would it be ?
- Fri Nov 28, 2014 10:18 pm
- Forum: Coleman Service & Repair
- Topic: Pilot going out
- Replies: 11
- Views: 19169
Re: Pilot going out
Is the light from the control board blinking and how many times?
- Wed Nov 05, 2014 8:44 pm
- Forum: Coleman Service & Repair
- Topic: DGAA77
- Replies: 9
- Views: 10407
Re: DGAA77
Where did you get it from? How much was it?
- Sat Nov 01, 2014 7:51 pm
- Forum: Coleman Service & Repair
- Topic: DGAA77
- Replies: 9
- Views: 10407
Re: DGAA77
I spent a lot of time comparing the DGAA77 service manual to mine. Where mine says code, yours says item. Based on the way I was originally thinking the intermittent code 5 should refer to the control board #031-01932-000. Fleabay has a good used one listed for $40 http://www.ebay.com/itm/Source-1-C...