Search found 22 matches

by MikeVila
Wed Dec 28, 2011 4:37 pm
Forum: Service & Repair of Other Brands
Topic: Interthetm E3 series. No a/c power. Help to find transformer
Replies: 9
Views: 24302

Re: Interthetm E3 series. No a/c power. Help to find transfo

Thx for the input thus far. I bought a better multimeter with capacitance and took off capacitor. Used screwdriver to discharge, honestly didn't notice it do anything. I have a 40+5.0UF 370vac. One side tested 40.24 and other 5.0. This is saying capacitor is good correct? Was it supposed to do somet...
by MikeVila
Mon Dec 26, 2011 5:14 pm
Forum: Service & Repair of Other Brands
Topic: Interthetm E3 series. No a/c power. Help to find transformer
Replies: 9
Views: 24302

Re: Interthetm E3 series. No a/c power. Help to find transfo

Went out and took access panel off my Intertherm heat pump to check out capacitor. Real easy to access. Looks as IRS a dual run capacitor as it has the 3 ports on top. It disnt look as if any oil was leaking or bulged but definitely rusty. System is about 7 years old. Going to try to test it. Need g...
by MikeVila
Mon Dec 26, 2011 1:08 pm
Forum: Service & Repair of Other Brands
Topic: Interthetm E3 series. No a/c power. Help to find transformer
Replies: 9
Views: 24302

Re: Interthetm E3 series. No a/c power. Help to find transfo

Also: for peace of mind. I used a crimp fitting that has the plastic collar at the end where the factory terminals are all metal. Basically you're normal electrical connector. Any issues?
by MikeVila
Mon Dec 26, 2011 12:53 pm
Forum: Service & Repair of Other Brands
Topic: Interthetm E3 series. No a/c power. Help to find transformer
Replies: 9
Views: 24302

Re: Interthetm E3 series. No a/c power. Help to find transfo

Very self gratifying. Another issue has come up actually right before this one. The heat pump fan isn't spinning. Just went out and it moves freely but when try to kick it on you can hear humming. Immediately shut off. We've been running emergency heat and fireplace. Did a little research and start ...
by MikeVila
Sun Dec 25, 2011 10:49 pm
Forum: Service & Repair of Other Brands
Topic: Interthetm E3 series. No a/c power. Help to find transformer
Replies: 9
Views: 24302

Re: Interthetm E3 series. No a/c power. Help to find transfo

Wow! No replies or input. Well I fixed it. One of the wires coing off the breaker of the furnace to the contractor was disconnected. Somehow the terminal had broken off. Quite odd. Simply cut off old and crimped new end on. Good to go. Wonder how much money I saved myself. Scary knowing loose live w...
by MikeVila
Sat Dec 24, 2011 10:00 pm
Forum: Service & Repair of Other Brands
Topic: Interthetm E3 series. No a/c power. Help to find transformer
Replies: 9
Views: 24302

Interthetm E3 series. No a/c power. Help to find transformer

Today my furnace kicked on and immediately kicked back off. After looking at my programmable Hunter thermostat it stated no a/c power. Checked and was connected solid. I proceeded to jumper wires to determine if was 24 volts to get fan or furnace to come on. Nothing. Did some research and looks like...
by MikeVila
Sat Dec 18, 2010 5:21 pm
Forum: Mobile Home Repair
Topic: Shower drain strainer removable to snake?
Replies: 4
Views: 2649

Shower drain strainer removable to snake?

I need to know if and how the shower drain strainer can be removed. I have tried but had no success and don't want to damage it. Thx. Mike.
by MikeVila
Tue Apr 21, 2009 12:29 am
Forum: Mobile Home Repair
Topic: Why does my water come out at an angle?
Replies: 8
Views: 8114

RE: Why does my water come out at an angle?

So was there debris in the screen?
by MikeVila
Mon Apr 20, 2009 3:13 pm
Forum: Mobile Home Repair
Topic: hole under water heater
Replies: 9
Views: 4110

Are you talking about the pressure relief valve??
by MikeVila
Mon Apr 20, 2009 3:11 pm
Forum: Mobile Home Repair
Topic: Regarding floor joist span?
Replies: 11
Views: 19467

RE: Regarding floor joist span?

Yeah my footers are definitely below the frost line. I thought he meant he was on a pad or something.
by MikeVila
Mon Apr 20, 2009 1:44 pm
Forum: Mobile Home Repair
Topic: Remodeling?
Replies: 1
Views: 1383

4. http://i12.photobucket.com/albums/a209/radraptor78/DSCN0176.jpg 5. The panel on the right side is going to be the access panel. I am going to tile it and it will be held in place with rare earth magnets and caulked using caulk that matches the grout.[/img] http://i12.photobucket.com/albums/a209/r...
by MikeVila
Mon Apr 20, 2009 1:41 pm
Forum: Mobile Home Repair
Topic: Remodeling?
Replies: 1
Views: 1383

Remodeling?

Curious to see some others' remodeling pics. I am currently working on my bathroom. Would like to see what others have done with there kitchen, baths, etc. Here are a few of mine in progress. 1. Here is what I had after I took out the garden tub (that had been leaking at the drain, probably from day...
by MikeVila
Mon Apr 20, 2009 1:34 pm
Forum: Mobile Home Repair
Topic: Why does my water come out at an angle?
Replies: 8
Views: 8114

RE: Why does my water come out at an angle?

LOL nice! Let us know if you get it shooting straight!
by MikeVila
Mon Apr 20, 2009 1:09 pm
Forum: Mobile Home Repair
Topic: Regarding floor joist span?
Replies: 11
Views: 19467

RE: Regarding floor joist span?

Thx for sharing yours NMBowtie. Chevy guy also I assume lol. You got any pics of your tiling? Actually the 1/2" offers no more structural strength than the 1/4". I forgot the exact specifics. The 1/2" is usually used for the walls and people usually use the 1/2" on floors if they...