Search found 7 matches

by WADE
Wed Mar 02, 2011 11:02 pm
Forum: Coleman Service & Repair
Topic: DGAT075BDD fan won't quit running.
Replies: 3
Views: 3716

Re: DGAT075BDD fan won't quit running.

Hi Robert, Thanks for the quick reply the board tested out ok, it was the limit switch right by the blower. I am guessing the furnace was running when I killed the power and it overheated just enough to pop it. I will have him keep an eye on it for a few days to make sure. Thanks again for your inpu...
by WADE
Tue Mar 01, 2011 9:48 pm
Forum: Coleman Service & Repair
Topic: DGAT075BDD fan won't quit running.
Replies: 3
Views: 3716

DGAT075BDD fan won't quit running.

I was working on my brother's electrical panel for another issue and turned on power. I just thought furnace was kicking on but after a little while he noticed it was not blowing heat and the fan will not shut off until the furnace is shut off, the green light is flashing 4 times as well. He shut it...
by WADE
Tue Apr 07, 2009 7:40 pm
Forum: Coleman Service & Repair
Topic: DGATO75BDD Having issues
Replies: 1
Views: 1503

DGATO75BDD Having issues

Hello, was wondering where you would get the fault codes for this furnace it appears to be flashing just once. Last night went to my brothers cause he was having issues with this furnace it was not heating it has a programmable thermostat and when he got there it kicked on for a minute then kicked o...
by WADE
Mon Nov 17, 2008 8:47 pm
Forum: Coleman Service & Repair
Topic: DGATO75BDD WONT WORK
Replies: 6
Views: 2277

RE: DGATO75BDD WONT WORK

I found it last night the wires running to the secondary limiter switch were grounding out. I can't believe they run those wires down through the back of the furnace with no grommets. They pass through bare metal in two places behind and under the blower motor.
by WADE
Sun Nov 16, 2008 9:47 am
Forum: Coleman Service & Repair
Topic: DGATO75BDD WONT WORK
Replies: 6
Views: 2277

RE: DGATO75BDD WONT WORK

Which wire do you check the line voltage at? I dont have wiring diagram. The white wire has 120 at board as well as the other 2 white wires right beside them but they are all common right? this is with no fuse in the board.
by WADE
Sat Nov 15, 2008 4:08 pm
Forum: Coleman Service & Repair
Topic: DGATO75BDD WONT WORK
Replies: 6
Views: 2277

RE: DGATO75BDD WONT WORK

I just put a new board in it still does same. Could the transformer be causing this? If I unplug the white line wire it wont blow but as soon as I touch that wire back to the transformer it blows. The voltage is 120 line and 26.9 load side. Guess it's space heaters for the rest of the weekend,at lea...
by WADE
Sat Nov 15, 2008 12:05 am
Forum: Coleman Service & Repair
Topic: DGATO75BDD WONT WORK
Replies: 6
Views: 2277

DGATO75BDD WONT WORK

Have a programmable thermostat that went haywire - furnace was functioning normally, then quit, and would not restart. Digital display, thermometer, etc. were not functioning properly, so replaced thermostat. Still wouldn't start (furnace or air conditioner). The fuse was blown on the circuit board,...