Search found 23 matches

by VCFD
Mon Jan 19, 2009 2:40 pm
Forum: Nordyne Service & Repair
Topic: CMF 80 PG
Replies: 1
Views: 1522

CMF 80 PG

It's been awhile since I've been on the site but I could use some help. I have a Miller CMF 80 PG furnace. 2 weeks ago, when I opened the house, the furnace was not running. The T-stat was set at 55 but the temp in the house was so low the digital readout only said "low" (luckily no pipes ...
by VCFD
Thu Jan 10, 2008 12:38 pm
Forum: Nordyne Service & Repair
Topic: Miller Furnace
Replies: 5
Views: 4218

RE: Miller Furnace

Thanks Robert. I will try and test it this weekend. Please let me know what you find.
by VCFD
Tue Jan 08, 2008 1:08 pm
Forum: Nordyne Service & Repair
Topic: Miller Furnace
Replies: 5
Views: 4218

RE: Miller Furnace

Thanks for getting back Robert. Yes, it is just the blower motor.
by VCFD
Thu Jan 03, 2008 1:16 pm
Forum: Nordyne Service & Repair
Topic: Miller Furnace
Replies: 5
Views: 4218

Miller Furnace

I have a Miller Model CMF80-PG propane furnace serial number MA0488-00496. When the T-stat calls for heat, the burner comes on and a short while later the blower kicks in but only runs for 2-3 minutes and shuts off for a minute or two before starting again. This continues until the set temperature i...
by VCFD
Mon Aug 13, 2007 2:03 pm
Forum: All Other HVAC Questions
Topic: Roof Jack Extension
Replies: 6
Views: 5211

RE: Roof Jack Extension

I was able to get the old roof jack installed this weekend. My whole problem was that I didn't have enough of the pipe showing through the roof to install the boot and properly seal it. I was able, (with much difficulty) to force the silicone boot over the part I had removed and then seal and instal...
by VCFD
Fri Aug 10, 2007 9:17 am
Forum: Mobile Home Repair
Topic: Almost there!
Replies: 11
Views: 5140

RE: Almost there!

Harry, the panels I used were made by American Building Components. Their website is; www.abcmetalroofing.com They have various locations throughout the US. The closest distributor to you looks like Adel, Georgia but they ship anywhere. The panels I used were 26ga. PBR. I ordered them full length at...
by VCFD
Thu Aug 09, 2007 12:43 pm
Forum: Mobile Home Repair
Topic: Almost there!
Replies: 11
Views: 5140

RE: Almost there!

I just looked at the manufacturers website for the corner trim profile. They have all of the dimensions and I think you're right. That might fit perfectly. I will measure everything up this weekend and verify and then see if they will take it back. It wont work on the front of the house though. On t...
by VCFD
Thu Aug 09, 2007 11:09 am
Forum: Mobile Home Repair
Topic: Almost there!
Replies: 11
Views: 5140

RE: Almost there!

Thanks JD! I had to replace a total of 12 sheets! All of the boards along the eaves on both sides and the one around the roof jack! All I have left to do now is figure out how I'm going to set the rake trim. The ones that I bought with the system are made for a 2x8 or a 2x10 rake board and mine are ...
by VCFD
Wed Aug 08, 2007 2:53 pm
Forum: All Other HVAC Questions
Topic: Roof Jack Extension
Replies: 6
Views: 5211

RE: Roof Jack Extension

Thanks Robert. I've been looking at the Nordyne store but for some reason I can't view the pictures, so I'm not sure if they are correct. From what I can see during my internet research, most of the extensions don't have the 4" flue, with a 6" intermediate, and an 8"outer. If I need t...
by VCFD
Wed Aug 08, 2007 12:10 pm
Forum: Mobile Home Repair
Topic: Almost there!
Replies: 11
Views: 5140

Almost there!

It took alot of work but I got the new metal roof on! I ran into a problem with the rake trim not fitting correctly so I have to work that out. I also have to finish sealing up the vent pipes etc. but I posted some pics of the entire project from start to finish in my profile. I'm so glad I decided ...
by VCFD
Wed Aug 08, 2007 11:59 am
Forum: All Other HVAC Questions
Topic: Roof Jack Extension
Replies: 6
Views: 5211

RE: Roof Jack Extension

I haven't heard from Robert yet but I posted a picture of the inside. Anyone have any ideas where I can get an extension? With the new roof there is not enough through the metal roof to put the boot on so I can seal it properly.

Thanks!
by VCFD
Mon Aug 06, 2007 2:31 pm
Forum: All Other HVAC Questions
Topic: Roof Jack Extension
Replies: 6
Views: 5211

Roof Jack Extension

I am in the process of putting a new metal roof and I need to extent the Roof Jack a minum of 8". I've been looking at numerous websites and can't find the exact match. The current pipe has a 4" inner, a 6 inch intermediate, and an 8 in outer. There is a picture of the complete assembly in...
by VCFD
Mon Jul 23, 2007 9:10 am
Forum: Mobile Home Repair
Topic: Roof Question
Replies: 4
Views: 3107

RE: Roof Question

Thanks for your help JD! I'll be sure to post some pictures.
by VCFD
Mon Jul 23, 2007 7:28 am
Forum: Mobile Home Repair
Topic: Roof Question
Replies: 4
Views: 3107

RE: Roof Question

Thanks for the response JD. I'll make sure I stay away from those marriage beams. The house does have vaulted ceilings. Oh, by the way, I did do a proper measurement of the roof slope and it is 3:12 I am ordering the rolled ridge material and metal ridge cap as well. Decided to go with 26 gauge pane...
by VCFD
Sun Jul 22, 2007 9:01 pm
Forum: Mobile Home Repair
Topic: Roof Question
Replies: 4
Views: 3107

Roof Question

Hello All! Thanks to your suggestions and comments, I've decided to go with a metal roof. I need to order it tomorrow but I have a question I hope someone can answer. I am ordering the panels to size so I need to be accurate with the legnth measurements. I am planning on adding a ridge vent so I rem...