- Topic: Outside fan not running, inside fan won't stop running
- Replies: 6
- Views: 5489
Robert, Here is what I have done so far and the current situation. Since the Fan relay tested bad I replaced it and it did take care of the blower fan running constantly but the breaker for the AC still kept tripping. I figured this would be the capacitor not holding enough charge and the AC pulling...
- Wed Aug 26, 2009 3:09 pm
- Forum: Coleman Service & Repair
- Topic: Outside fan not running, inside fan won't stop running
- Replies: 6
- Views: 5489
RE: Outside fan not running, inside fan won't stop running
Robert,
Thanks so much for the through reply. I will have to check the items you mentioned when I get home later. Can you please give me ordering info so I can have a rough figure in my head, if it is not too much to ask? Thanks again
Thanks so much for the through reply. I will have to check the items you mentioned when I get home later. Can you please give me ordering info so I can have a rough figure in my head, if it is not too much to ask? Thanks again
- Wed Aug 26, 2009 8:19 am
- Forum: Coleman Service & Repair
- Topic: Outside fan not running, inside fan won't stop running
- Replies: 6
- Views: 5489
Outside fan not running, inside fan won't stop running
Having an issue with my Split AC Unit. I am going to try to be as descriptive as possible so please forgive the length. Inside Unit - EB12B Outside Unit - BRCQ0361BB Age 13 Years for both units About 1 week ago I noticed the AC was not blowing cold air, so I checked the condenser (outside) fan and n...
- Sat Jan 10, 2009 10:10 pm
- Forum: Mobile Home Repair
- Topic: Redownloading Manual
- Replies: 3
- Views: 1800
RE: Redownloading Manual
I have called the store 3 times and always got the same answer "They would send another download link" never got one, even gave them 2 different email addresses in case one was blocking them.
- Sat Jan 10, 2009 9:42 pm
- Forum: Mobile Home Repair
- Topic: Redownloading Manual
- Replies: 3
- Views: 1800
Redownloading Manual
I bought the Mobile Home Repair Manual a while back. Due to a computer crash I lost ( I know, back up, funny seeing as I work in IT and I did not back up my files) the manual. I have contacted Aberdeen a few times and each time was told they would send me another download link. This has been a month...
- Mon Feb 18, 2008 11:34 am
- Forum: Mobile Home Repair
- Topic: Hole in tub!!
- Replies: 2
- Views: 2035
I would really look at replacing the tub instead of patching. Long story short I tried to patch a crack in a bathtub a while back and it seemed to work well. Never saw any cracks in the patch. Started to see mold on the walls and bought the replacement fiberglass tub. Now I am having to restud, cut ...
- Mon Feb 11, 2008 8:05 am
- Forum: Mobile Home Repair
- Topic: Doing your own work and Home Owners Insurance
- Replies: 4
- Views: 2573
Doing your own work and Home Owners Insurance
A brief history. We live in a 54x27 1995 Fleet-wood Double-wide. We have lived in the home since 1997 and a few years ago had a mouse get in and die under the Garden Tub in the Master Bath. I took out the tub, removed enough of the sub-floor to get the mouse out. This was about 3 years ago. I replac...
- Wed Jan 23, 2008 5:29 pm
- Forum: Mobile Home Repair
- Topic: Lowering Ceiling for Better Insulation
- Replies: 6
- Views: 3177
RE: Lowering Ceiling for Better Insulation
Great points you all have made. The added weight would be a huge concern. Sounds like I would be better off using that money to plant some shade trees by the house, right now my house is directly exposed to the sun on the east side from morning till about 3pm. Also going to upgrade to some better wi...
- Wed Jan 23, 2008 12:23 pm
- Forum: Mobile Home Repair
- Topic: Lowering Ceiling for Better Insulation
- Replies: 6
- Views: 3177
RE: Lowering Ceiling for Better Insulation
Bob thanks for the welcome, and the fast and thorough response. I am mainly concerned about heat/cool air loss, We have fans in all rooms of the home right now. I really got concerned with energy efficiency this summer as our AC unit would never turn off and still would only cool to 78-80 degrees, i...
- Wed Jan 23, 2008 11:47 am
- Forum: Mobile Home Repair
- Topic: Lowering Ceiling for Better Insulation
- Replies: 6
- Views: 3177
Lowering Ceiling for Better Insulation
Hi all, I have a 1995 Fleetwood, 54x27 DW that has the peaked ceilings. While replacing a light fixture this summer I noticed there is only about 6 inches between the ceiling and the roof of my home. I also noticed how extremely hot it was in that area between the roof and ceiling. After looking at ...