Search found 3 matches
- Fri Dec 02, 2011 9:38 pm
- Forum: Nordyne Service & Repair
- Topic: Nordyne MMHA070ABHR-01 Gas Furnace
- Replies: 2
- Views: 5703
Re: Nordyne MMHA070ABHR-01 Gas Furnace
Update: The electronic control module was bad in my furnace. Just a note of caution to anyone who has the United Technologies 1018 Series Hot Surface Ignition modules, there are several versions of this module and they are not interchangeable. I was fortunate to ask a service tech a lot of questions...
- Wed Nov 30, 2011 9:36 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne MMHA070ABHR-01 Gas Furnace
- Replies: 2
- Views: 5703
Re: Nordyne MMHA070ABHR-01 Gas Furnace
Update: I did some more troubleshooting and was able to jumper the burner fan with 120V and it runs fine, so the burner fan itself is good. If its the control module, does anyone have a way to look up the replacement part number?
- Wed Nov 30, 2011 9:09 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne MMHA070ABHR-01 Gas Furnace
- Replies: 2
- Views: 5703
Nordyne MMHA070ABHR-01 Gas Furnace
I searched the board but didn't find a post with a similar question. I tried to do the start up on my gas furnace in a mobile home today and the burner fan won't run. I have 120V to the furnace and the house blower fan runs fine on fan only mode. There is only 86 volts to the burner fan. Is this nor...