Search found 2 matches

by Doyle318
Wed Oct 05, 2011 7:01 pm
Forum: Nordyne Service & Repair
Topic: Intertherm / Nordyne elements cylces on
Replies: 2
Views: 3419

Re: Intertherm / Nordyne elements cylces on

Just to help thise who may have experienced this problem. This unit has two heating elements stacked on top of each other. The lower unit had a insulator that had failed and allowed the wire from the element to touch the other element. This caused some weird reading when checking the current and the...
by Doyle318
Sun Oct 02, 2011 4:50 pm
Forum: Nordyne Service & Repair
Topic: Intertherm / Nordyne elements cylces on
Replies: 2
Views: 3419

Intertherm / Nordyne elements cylces on

I have a Intertherm / Nordyne FEH-020HA-04. I noticed that the heating elements are cycling on when the a/c is running. After a few checks I found that unless I throw the circuit breaker the element cycles even when unit is not running. I keep some parts here at home and changed the thermostat to no...