Search found 3 matches

by strick87
Sun Jan 23, 2011 8:32 pm
Forum: Nordyne Service & Repair
Topic: Hey everyone....
Replies: 5
Views: 3948

Re: Hey everyone....

THE SEQUENCER IS LOCATED IN A PANEL RIGHT BELOW YOUR BLOWER MOTOR. THER IS A METAL COVER THAT IF REMOVED WILL EXPOSE THE SEQUENCER ALONG WITH LIMITS AND HEATING ELEMENTS. YOU WILL ALSO SEE TWO BREAKERS BEFORE YOU REMOVE THE COVER. YOU WILL WANT TO TURN THOSE BREAKERS OFF BEFORE ROMOVING COVER TO KIL...
by strick87
Sat Jan 22, 2011 2:47 pm
Forum: Nordyne Service & Repair
Topic: Hey everyone....
Replies: 5
Views: 3948

Re: Hey everyone....

sounds like you have one of two things happening. sounds like sequencer is not working properly. or also check filters, the clicking your hearing may also be limit switches tripping on and off due to lack of airflow or blower not coming on properly. run your fan on manual on. and see how it works. i...
by strick87
Fri Jan 21, 2011 10:29 pm
Forum: Nordyne Service & Repair
Topic: limt tripping
Replies: 1
Views: 2372

limt tripping

I have a E2EB-015HA FURNACE I AM WORKING ON. WHEN I FIRST LOOKED AT FURNACE THE DOUBLE STACK LIMIT WAS TRIPPING WITH BLOWER DOOR ON. WOULD TAKE OFF BLOWER DOOR AND LIMIT WOULD NOT TRIP. REPLACED LIMIT WHICH IS 190 DEGREE. SAME PROBLEM WITH NEW LIMIT. AFTER TALKING WITH HOMEOWNER HE TOLD ME DID NOT B...