Search found 2 matches

by kiko88
Thu Jan 06, 2011 9:14 am
Forum: Nordyne Service & Repair
Topic: Nordyne Intertherm M1MB 056A BW won't light
Replies: 3
Views: 4760

Re: Nordyne Intertherm M1MB 056A BW won't light

The problem was the board was giving me 12v at the gas valve. Will have to replace the board. Sometimes it gives the 24v needed to start the gas valve. Weird. Faulty board
by kiko88
Sat Dec 25, 2010 6:56 pm
Forum: Nordyne Service & Repair
Topic: Nordyne Intertherm M1MB 056A BW won't light
Replies: 3
Views: 4760

Nordyne Intertherm M1MB 056A BW won't light

Status light is red b4 I try to turn on the heater. Call for heat, the draft inducer motor turns on, the ignitor glows orange and after a couple of minutes nothing happens and then shuts down with no status indicators after that. Have 24v at the transformer. Have gas at the gas valve. Have 115v at t...