Search found 205 matches

by jpingram5
Sun Jun 30, 2013 5:07 pm
Forum: Mobile Home Repair
Topic: Tankless Hot water heaters
Replies: 8
Views: 4678

Re: Tankless Hot water heaters

Those electric ones can use up to 6 slots on the circuit panel so make sure you have space. There's no real size but more like how many things you want to run hot water all at once? Most will list what they are capable of ex; like some can do 2 showers and a sink all at once and flow at 5.0gpm and s...
by jpingram5
Wed Jun 12, 2013 7:00 pm
Forum: Nordyne Service & Repair
Topic: MGH-055-ABWN-06 ac noise issue
Replies: 6
Views: 9523

Re: MGH-055-ABWN-06 ac noise issue

Is the gurgling sound only during cooling season?
by jpingram5
Wed May 29, 2013 3:58 pm
Forum: Mobile Home Repair
Topic: New Here
Replies: 11
Views: 4376

Re: New Here

Yeah, its kinda screwy they won't let you move it even though the moving company insures it if something was to go bad. I guess their more concerned about getting all that interest money and wouldn't want a payoff from insurance if it would end up totaled :roll:
by jpingram5
Wed May 29, 2013 3:54 pm
Forum: All Other HVAC Questions
Topic: portable standup AC units
Replies: 2
Views: 6149

Re: portable standup AC units

I wouldn't see why not. They usually come with a low profile window adapter to fill in the space to keep it sealed. Probably use a little weather stripping to help. Either that or install a dryer vent kit to use it dedicated throw the wall & just cap it off in the winter seasons.
by jpingram5
Wed May 29, 2013 5:05 am
Forum: Mobile Home Repair
Topic: New Here
Replies: 11
Views: 4376

Re: New Here

I was able to get my mortgage down low enough that I used a personal line of credit from my credit union to pay it off. Also the park can charge you a fee to move it out I found also, how nice. I have a piece a land that I just have to pay off before I can finally move it on to the land. But yeah, y...
by jpingram5
Wed May 29, 2013 4:53 am
Forum: All Other HVAC Questions
Topic: a/c blows to the ceiling...
Replies: 3
Views: 6393

Re: a/c blows to the ceiling...

Got a model number off the Air Handler in the closet? If the fan is Multi-Speed you should be able to adjust it down but I do not know if that would make that big difference. You should have speeds, High, Medium-High, Medium-Low, Low. It's probably set on High right now and I wouldn't go any lower t...
by jpingram5
Sun May 26, 2013 2:58 pm
Forum: Service & Repair of Other Brands
Topic: Intertherm Model MGH-065 random turn-on
Replies: 5
Views: 24915

Re: Intertherm Model MGH-065 random turn-on

If you can get your hands another a used working thermostat or a new cheap one, I would suggest trying that first just to eliminate the Thermostat. Do you ever here the Thermostat click when the heat randomly turns on? That's where I would start I've come across a lot strange problems with thermosta...
by jpingram5
Sun May 12, 2013 4:40 pm
Forum: Nordyne Service & Repair
Topic: replacing furnace
Replies: 4
Views: 8278

Re: replacing furnace

The CMF95 is the high efficiency one right? Like 95% or something like that I think. It will be vented out in PVC and you would need a roof-jacket adapter for the new PVC vent setup. The sell a kit that should fit your existing vent setup.
by jpingram5
Fri Apr 26, 2013 9:55 pm
Forum: Mobile Home Repair
Topic: RADIANT FLOOR HEATING IN 14X76
Replies: 7
Views: 3275

Re: RADIANT FLOOR HEATING IN 14X76

Anything that can effect the pressure on a boiler will cause problems. Some might be okay with 12psi but some will require at least 16psi. This is a really complicated system that needs fine tuning to make it work right. It sounds like you have a decent game plan but a major part comes down to the u...
by jpingram5
Wed Apr 10, 2013 6:53 pm
Forum: Service & Repair of Other Brands
Topic: I am haveing a problem with my furnace. It works intermetent
Replies: 7
Views: 26246

Re: I am haveing a problem with my furnace. It works interme

Just realized this is and old thread brought back to life by some spammer. Lol, hope you got your problem solved!
by jpingram5
Wed Apr 10, 2013 6:51 pm
Forum: Service & Repair of Other Brands
Topic: I am haveing a problem with my furnace. It works intermetent
Replies: 7
Views: 26246

Re: I am haveing a problem with my furnace. It works interme

Have you been using a meter to see where or where not you have voltage? At the gas valve, place 1 meter lead on one of the wires/terminal and the other meter lead on the other wire/terminal. Set your thermostat to call for heat and then check to see if you are getting 24v there. If you are getting 2...
by jpingram5
Sat Apr 06, 2013 9:08 pm
Forum: Mobile Home Repair
Topic: Do we need vaporbarrier under new floor?
Replies: 5
Views: 2647

Re: Do we need vaporbarrier under new floor?

Not to go off topic but could you shine some light on us with the radiant heating part perhaps in separate thread? Just interested in seeing how you are going about doing it. I do not think I heard of anyone using radiant floor heat in a mobile home before, assuming this is a hydronic system.
by jpingram5
Thu Apr 04, 2013 5:54 am
Forum: Nordyne Service & Repair
Topic: stops heating
Replies: 8
Views: 11783

Re: stops heating

Use some No Rinse Evaporator cleaner if you can get some. That stuff works great for me.
by jpingram5
Sun Mar 31, 2013 8:28 am
Forum: All Other HVAC Questions
Topic: replacing thermostat
Replies: 4
Views: 9342

Re: replacing thermostat

Mark the green wire on the RH/RC terminal with a marker so you know that's what it is. Put them back just like they were on the new thermostat. You can buy "Heat Only" thermostats. That will have the basic terminals or if you get one made for like 3 heat 2 cool you'll have many extra termi...