Search found 5 matches
- Mon Feb 04, 2019 6:35 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne E1EH-012HA
- Replies: 2
- Views: 24709
Re: Nordyne E1EH-012HA
Removed from the unit of course. It does not mean they are accurate just that they aren't totally wasted.
- Mon Feb 04, 2019 6:34 am
- Forum: Nordyne Service & Repair
- Topic: Nordyne E1EH-012HA
- Replies: 2
- Views: 24709
Re: Nordyne E1EH-012HA
Not very familiar with that unit, but I would be looking on the way side of a bimetal limit switch being fried, once you find the two for the blower circuit on is for over temp shutdown and one is to turn the fan on when desired temp is reached, both can be checked for approximate function with a to...
- Mon Feb 04, 2019 6:31 am
- Forum: Nordyne Service & Repair
- Topic: wifi thermostat and I need a "C" wire
- Replies: 2
- Views: 23415
Re: wifi thermostat and I need a "C" wire
If there is no common you're only other choice is adding a 120v → 24v transformer to the circuit.
- Mon Feb 04, 2019 6:29 am
- Forum: Nordyne Service & Repair
- Topic: Need to remove a stripped Allen wrench-type plug from the OUT PRESS port on top of gas valve
- Replies: 1
- Views: 47772
Re: Need to remove a stripped Allen wrench-type plug from the OUT PRESS port on top of gas valve
A little late to be helpful but for anyone else, you're best option is to order a strip socket for the size Allan head you stripped, either online or a tool truck if available to you. That being said neither is very convenient in a pinch. My suggestions would follow Try upping to next closest size y...
- Thu Nov 22, 2018 10:15 am
- Forum: Nordyne Service & Repair
- Topic: Intertherm standing pilot LPG burner 77 BTU IN gas valve mounting plate gets hot ( not warm).
- Replies: 1
- Views: 72512
Re: Intertherm standing pilot LPG burner 77 BTU IN gas valve mounting plate gets hot ( not warm).
What is the source of your heat. Is the coil in the gas valve getting hot, or is your 3/4 " burner tube conducting from the burner it's self. If the burner is heating up the gas valve, try adjusting the placement of your pilot flame, check your orifice as well, make sure it is a lpg orifice, th...