Search found 9 matches

by bryantyme
Tue Jan 04, 2011 5:12 pm
Forum: Nordyne Service & Repair
Topic: Small black furnace blower motor continues to run
Replies: 5
Views: 3432

Re: Small black furnace blower motor continues to run

Robert, I went to change the relay but noticed it was different from the original. I thought I had the wrong one. After looking up the numbers had found that this relay 621867 replaced the original 660190. The places for connections are different. The original had 4 places to hook up to with one of ...
by bryantyme
Thu Dec 16, 2010 8:16 pm
Forum: Nordyne Service & Repair
Topic: Small black furnace blower motor continues to run
Replies: 5
Views: 3432

Re: Small black furnace blower motor continues to run

Thanks for the info.
I will order one and try it out.
by bryantyme
Thu Dec 16, 2010 11:08 am
Forum: Nordyne Service & Repair
Topic: Small black furnace blower motor continues to run
Replies: 5
Views: 3432

Small black furnace blower motor continues to run

intertherm furnace MGHA-090ABPQ-01 This Part 115 Volt Inducer Furnace Blower Motor (Nordyne/Intertherm) Continues to run periodically. I understand it needs to exhaust any fumes that may be in there. It sometimes needs to be hit with something to get it to turn off. Is there a bad relay in there tha...
by bryantyme
Fri Mar 27, 2009 8:59 am
Forum: Nordyne Service & Repair
Topic: Furnace cycles on and off too frequently
Replies: 12
Views: 6140

RE: Furnace cycles on and off too frequently

Robert I have not been there to check it recently. The first thing I will do is check to see if switches are in the correct ports. When I cleaned it last I did not find a shield laying at the bottom so I'm thinking it is still in place. I will be checking it over again April 8th. If the switches are...
by bryantyme
Wed Mar 25, 2009 10:30 am
Forum: Nordyne Service & Repair
Topic: Furnace cycles on and off too frequently
Replies: 12
Views: 6140

RE: Furnace cycles on and off too frequently

Any luck finding the adj. switch?

Bry
by bryantyme
Mon Mar 23, 2009 5:44 pm
Forum: Nordyne Service & Repair
Topic: Furnace cycles on and off too frequently
Replies: 12
Views: 6140

RE: Furnace cycles on and off too frequently

Hi Robert,

I believe the heat anticipater slide bar is set correctly.
I have tried sliding it into other positions but have had no effect.
What is it supposed to be on?
Can you tell me what the model number would be on the adj. fan switch.

Thanks for the info,

Bry
by bryantyme
Mon Mar 23, 2009 1:54 pm
Forum: Nordyne Service & Repair
Topic: Furnace cycles on and off too frequently
Replies: 12
Views: 6140

RE: Furnace cycles on and off too frequently

Robert,

I replaced the fan switch and thoroughly cleaned out everything I could take apart.
I Still have the same issue.
I read somewhere else that the sensors may need to have a sheild over them.
Does this funace need a sheild over one or both of the sensors? And if so which one?
by bryantyme
Wed Jan 07, 2009 3:53 pm
Forum: Nordyne Service & Repair
Topic: Furnace cycles on and off too frequently
Replies: 12
Views: 6140

RE: Furnace cycles on and off too frequently

Thanks Robert.

I will replace the fan switch and see if that works.
by bryantyme
Tue Jan 06, 2009 12:19 am
Forum: Nordyne Service & Repair
Topic: Furnace cycles on and off too frequently
Replies: 12
Views: 6140

Furnace cycles on and off too frequently

Intertherm model MGHA-090ABPQ-01 I keep my thermostat about 50 degrees during winter when I am not at my second home. When I arrive I turn up the thermostat and the furnace cycles on and off frequently until reaching its desired temp. I was thinking this is because it is sucking cold air into the bu...