Search found 10 matches
- Mon Jan 27, 2014 7:08 am
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
yes it does, just as you described, a collector joint between inducer and exhaust with short tube running to the top of collector box,
- Sat Jan 25, 2014 9:39 pm
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
between the last two cleanings I posted, "I did", (and one other time in late fall 2nd year I owned the house, before all this happened, I was checking the furnace for winter and I had lots of water in inducer, that's when I learned to check the drain to see if it needed it be cleaned) pul...
- Wed Jan 22, 2014 6:21 am
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
Update; locked out again, after 2 hours, sucked out all drain vents with shop vacuum, then removed blower assembly, set end of shop vacuum up in exchanger, used compressed air to blow out secondary "gently" between coil fins, re vacuumed, put back together, lasted through the night, "...
- Tue Jan 21, 2014 12:33 pm
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
FIXED IT!! Removed Blower Assembly, Carefully used a shop vac with brush attachment, duct tape small flashlight to end of hose so as to not drop anything down there also duct taped brush attachment, cleaned coil for secondary heat exchanger, put back together
- Sat Jan 04, 2014 8:59 am
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
Natural gas is dirty, we are using gas directly from a well on my property, I have been told that the pressure will fluctuate, and the line is 600 lf with one coupling, may be leaking? the line is only 10 yrs old, but you would think the flame sensor would signal the furnace to turn off the fan with...
- Thu Jan 02, 2014 5:58 am
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
There is 2 90 degree elbows in the flu system, from furnace thru ceiling turns left along ceiling joist to bottom edge of roof, at soffit, turns up thru roof, they 12 inches apart, intake is 12 inches above roof with 2 90's turned down, and turned right, away from the exhaust, exhaust is 10 inches a...
- Wed Jan 01, 2014 5:13 am
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
Thanks greg for the tip , you know when I went to clean the "exhaust vent" I said to myself, why is there no vent cap for the pvc vent, one was never put on when the house was installed, and not mentioned any where in the manual, but one is for sale. I will let you know if it worked thank ...
- Tue Dec 31, 2013 6:16 am
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
INTERTHERM M3RL Series 90+ Condensing Furnace UNIT MODLE NUMBER: M3RL0ABW UNIT SERIAL NUMBER: M3A050602044 BLOWER MOTOR: 1/2 hp FUEL TYPE: Natural Gas Furnace Input: 80,000 (Btuh) Still having problems with limit switch on inducer. flash code "one" furnace "operatation of sequence&quo...
- Mon Jan 28, 2013 8:07 pm
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Re: Natural Gas Furnace
Thank-You for your time!! Dale
- Sun Jan 27, 2013 4:20 pm
- Forum: Nordyne Service & Repair
- Topic: Natural Gas Furnace
- Replies: 18
- Views: 22521
Natural Gas Furnace
We purchased our home in 2008, a couple of days ago it got colder and we turned the furnace up past 70, overnite woke up to 55 and furnace was still blowing. I reset "vent safety switch, went through sequence of operation, house warmed up to 65 and started blowing cold air again, and again and ...