Search found 10 matches
- Thu Nov 28, 2013 3:33 pm
- Forum: Coleman Service & Repair
- Topic: Blend Air Service
- Replies: 3
- Views: 6873
Re: Blend Air Service
Thanks guys! I actually ended up disconnecting the Blend Air and I can sleep now!
- Sun Nov 17, 2013 6:47 pm
- Forum: Coleman Service & Repair
- Topic: Can I disconnect BlendAir permanently?
- Replies: 9
- Views: 11928
Re: Can I disconnect BlendAir permanently?
Thanks, Dale!! I'll give that a try.
- Sat Nov 16, 2013 6:52 pm
- Forum: Coleman Service & Repair
- Topic: Can I disconnect BlendAir permanently?
- Replies: 9
- Views: 11928
- Thu Nov 14, 2013 10:00 am
- Forum: Coleman Service & Repair
- Topic: Can I disconnect BlendAir permanently?
- Replies: 9
- Views: 11928
Re: Can I disconnect BlendAir permanently?
Thank you!!
- Tue Nov 05, 2013 10:08 am
- Forum: Coleman Service & Repair
- Topic: Can I disconnect BlendAir permanently?
- Replies: 9
- Views: 11928
Re: Can I disconnect BlendAir permanently?
One last question -- or rather, confirming that what I will do is correct. In the photo, I am holding the green connections. I will pull the darker green wire (from Blend Air) out of that cluster and cap it with a wire nut. That leaves the thicker light green from the furnace and the thin green wire...
- Thu Oct 31, 2013 4:18 pm
- Forum: Coleman Service & Repair
- Topic: Can I disconnect BlendAir permanently?
- Replies: 9
- Views: 11928
Re: Can I disconnect BlendAir permanently?
Dale, thanks for responding! I've seen posts on how to disconnect, so I know it can be done. 1. Without Blend Air will the roof vents I have be adequate to keep the air moving (and moisture at bay)? Can you clarify: when you say "...when the blower comes on..." I assume you mean the furnac...
- Thu Oct 31, 2013 1:07 pm
- Forum: Coleman Service & Repair
- Topic: Can I disconnect BlendAir permanently?
- Replies: 9
- Views: 11928
Can I disconnect BlendAir permanently?
I have '92 Nashua with Blend Air 7681-7701 installed. Had furnace serviced today and asked tech to look at the Blend Air motor because it's become unbearably loud and I can't sleep. Options he offered were to replace the motor or permanently disconnect it. He said I had plenty of roof venting and th...
- Sun Sep 01, 2013 7:52 pm
- Forum: Coleman Service & Repair
- Topic: Blend Air Service
- Replies: 3
- Views: 6873
Blend Air Service
My Blend Air needs service. In the 7 years since I purchased my 1992 home, it has gone from a barely noticeable hum to running so loud I can't sleep. Question: Can a traditional furnace company service it, or does it require service by someone with special knowledge about this type of system? Thanks...
- Tue Apr 08, 2008 11:15 pm
- Forum: Mobile Home Repair
- Topic: Tub Plumbing Question: Simple (I think but don't guarantee)
- Replies: 15
- Views: 7163
- Tue Apr 08, 2008 11:03 pm
- Forum: Mobile Home Repair
- Topic: Can I install a "normal" bathtub?
- Replies: 2
- Views: 2639
Can I install a "normal" bathtub?
Hi, I have a 1997 Nashua with a styrofoam tub that I'd like to replace. It seems to be a standard size - 30" x 60". What do I need to consider when replacing? 1. In reading this GREAT forum, I'm deducing that there may be plumbing under the tub, is that right? 2. If so, plumbing would need...