Coleman Gas Furnace Parts Quick Reference Guide

Determining Coleman Gas Furnace Parts

The best way to determine what part number you need it to look for the number printed on the part itself. If that’s not possible, then this cheat sheet may help you determine which parts you need for many common Coleman gas furnaces.

To use this cheat sheet, first locate the model number of your furnace by looking at the data plate on the front of your furnace. It may look something like this: DGAAO56BDTA. The model number breaks down as follows:

  • the first 4 letters is the model (DGAA)
  • the numbers in the middle indicate the BTU’s in thousands (056)
  • the last 3 or 4 letters is the series (BDTA).

If the model number contains mostly numbers (like 7975B856) , the first four numbers are the model and the last three are the series.

TIP: To search for your furnace on this page, place your cursor below the page heading and type ‘Control F’ and enter the model number.

Click here for Coleman Furnace Parts
Click here for Furnace Troubleshooting Help

ELECTRONIC IGNITION FURNACE MODELS

Below is a common parts list for the following furnace models:
DGAA056BDTA, DGAA070BDTA, DGAA077BDTA, DGAA090BDTA, DGAH056BDTA, DGAH077BDTA

PART # DESCRIPTION USED ON MODELS USED ON SERIES
025-35358-000 Upper Limit Switch All All
373-19801-820 Booster Assembly w/Motor & Centrifugal Switch All All
024-31950-000 Blower Motor (requires new motor mount assembly) DGAA All
024-31948-000 Blower Motor DGAH All
024-20063-000 Run Capacitor for 024-31950-000 Motor DGAA All
373-19806-100 Motor Mount Assembly (required for all replacement DGAAO motors) DGAA All
025-35354-000 Flame Sensor All All
1474-052P Ignitor All All
024-27666-000 Pressure Switch All All
7990-320P Integrated Control Board All All
2940A3541 Transformer 115-24V, 40VA All All
7990-328P Gas Valve All All

Below is a common parts list for the following furnace models:

DGAT056BDF, DGAT070BDF, DGAT075BDF, DGAT090BDF
DGAT056BDE, DGAT070BDE, DGAT075BDE, DGAT090BDE
DGAT056BDD, DGAT070BDD, DGAT075BDD, DGAT090BDD
DGAT056BDC, DGAT070BDC, DGAT075BDC, DGAT090BDC
DGAT056ADC, DGAT070ADC, DGAT075ADC, DGAT090ADC
DGAT056BDA, DGAT070BDA, DGAT075BDA, DGAT090BDA
DGAT056ADA, DGAT070ADA, DGAT075ADA, DGAT090ADA

DLAS056BDF, DLAS070BDF, DLAS075BDF, DLAS090BDF
DLAS056BDE, DLAS070BDE, DLAS075BDE, DLAS090BDE
DLAS056BDD, DLAS070BDD, DLAS075BDD, DLAS090BDD
DLAS056BDC, DLAS070BDC, DLAS075BDC, DLAS090BDC
DLAS056ADC, DLAS070ADC, DLAS075ADC, DLAS090ADC

DGAM056BDF, DGAM070BDF, DGAM075BDF, DGAM090BDF
DGAM056BDE, DGAM070BDE, DGAM075BDE, DGAM090BDE
DGAM056BDD, DGAM070BDD, DGAM075BDD, DGAM090BDD
DGAM056BDC, DGAM070BDC, DGAM075BDC, DGAM090BDC
DGAM056ADC, DGAM070ADC, DGAM075ADC, DGAM090ADC

PART # DESCRIPTION USED ON MODELS USED ON SERIES
7990-314P Booster Motor All BDF
7990-317P Booster Motor All BDE, BDD
7995-3169 Booster Motor All BDC, ADC, ADA, BDA
1474-052P Ignitor All All
024-27666-000 Pressure Switch All BDF
7990-320P Integrated Control Board All BDE, BDF, BDD
1474-0061/A Ignition Module All BDC, ADC
1474-0041 Ignition Module All BDA, ADA
7975-3881 Flame Sensor All BDE, BDF, BDD
2940A3541 Transformer 115-24V, 40VA All (except DLAS-BDC) BDF, BDE, BDD, BDC, ADC
7945-3551 115-24V 15VA Transformer All (incl DLAS-BDC) BDA, ADA
7990-328P Gas Valve All All
7966-311P Blower Motor (56, 70 or 75,000 btu’s) DGAT, DLAS All
1468-212P Blower Motor (90,000 btu’s) DGAT, DLAS All
1468-220P Blower Motor DGAM All
7956-3671 Booster Relay All BDC, ADC
8665-5701 Booster Relay All BDA, ADA
7975-3771 A/C Relay All BDC, ADC
7956-5771 Damper Assembly All BDA, ADA
7624A3591 Upper Limit Switch (manual) All All
7990-3591 Upper Limit Switch (auto) All All
7975-3281 Fan Switch All BDC, ADC, BDA, ADA

Below is a common parts list for the following furnace models:
7956-656/D, 7970-656/D, 7995-656/D

PART # DESCRIPTION USED ON MODELS USED ON SERIES
7995-3169 Booster Motor All All
1474-052P Ignitor All All
7945-3551 Transformer 115-24V, 15VA All All
7990-328P Gas Valve All All
7966-311P Blower Motor (56, 70 or 75,000 btu’s) 7956, 7970 All
1468-212P Blower Motor (90,000 btu’s) 7995 All
1474-0041 Ignition Module All All
8665-5701 Booster Relay All All
7956-5771 Damper Assembly All All
7624A3591 Upper Limit Switch (manual) All All
7975-3281 Fan Switch All All

SPARK IGNITION FURNACE MODELS

Below is a common parts list for the following furnace models:
7970C656, 7975C656, 7995C656
7966A656, 7975A656, 7995A656
7966-656, 7975-656, 7995-656

PART # DESCRIPTION USED ON MODELS USED ON SERIES
7995-3169 Booster Motor All All
7945-3551 Transformer 115-24V, 15VA All All
7990-328P Gas Valve All All
7966-311P Blower Motor (56, 70 or 75,000 btu’s) 7966, 7970, 7975 All
1468-212P Blower Motor (90,000 btu’s) 7995 All
8665-5701 Booster Relay All All
7956-5771 Damper Assembly All All
7624A3591 Upper Limit Switch (manual) All All
7975-3281 Fan Switch All All
7995-3061 Electrode – Sparker All All
7995-3081 Ignition Module All All

AUTO RELIGHT PILOT FURNACE MODELS

Below is a common parts list for the following furnace models:
DGRT056AUA, DGRT070AUA, DGRT075AUA
DGRT056AUB, DGRT070AUB, DGRT075AUB

PART # DESCRIPTION USED ON MODELS USED ON SERIES
7956-336P Gas Valve All AUA, AUB
7970-377P Electrode – Sparker All AUA, AUB
7970-378P/B Ignition Module All AUA, AUB
3110-3311/A Ignitor Relay All AUB
2631-3481 Thermocouple All AUA, AUB
2940A3541 Transformer 115-24V, 40VA All All
7966-311P Blower Motor All All
7624A3591 Upper Limit Switch (manual) All All
7975-3281 Fan Switch All All
7975-3771 A/C Relay All AUB

STANDING PILOT FURNACE MODELS

Below is a common parts list for the following furnace models:
7956C859, 7970C859, 7975C859, 7995C859 (Presidential, propane)
7956C856, 7970C856, 7975C856, 7995C856 (Presidential, natural gas)
7956B856, 7966B856, 7970B856, 7975B856, 7995B856 (Presidential, natural gas)
7956A856, 7966A856, 7970A856, 7975A856, 7995A856 (Presidential, natural gas)
7956-856, 7966-856, 7970-856, 7975-856, 7995-856 (Presidential, natural gas)

PART # DESCRIPTION USED ON MODELS USED ON SERIES
7956A5851 Burner Assembly All All
2631-3481 Thermocouple All All
7945-1671/B Pilot Tube All All
7956A3771 Blower Control All B
7995-3169 Booster Motor 7995 All
7945-3551 Transformer 115-24V, 15VA All All
7966-311P Blower Motor 7956, 7970, 7975 All
1468-212P Blower Motor 7995 All
8665-5701 Booster Relay 7995 All
7624A3591 Upper Limit Switch (manual) All All
7975-3281 Fan Switch All All
7956-5771 Damper Assembly All C
7956-336P Gas Valve All All
7945-3281/A Lower Limit Switch (0-140, C-110) 7956 All
7970-3281/A Lower Limit Switch (0-145, C-115) 7966, 7979, 7975 All
7995-3281/A Lower Limit Switch (0-150, C-120) 7995 All

Below is a common parts list for the following furnace models:
7680C856, 7680B856, 7670C856, 7670B856, 7665-856, 7663B856, 7656B856, 7656F856, 7655-856, 7654-856 (ng)
7680C859, 7680B859, 7670C859, 7670B859, 7665-859, 7663B859, 7656B859, 7656F859, 7655-859, 7654-859 (lp)

PART # DESCRIPTION USED ON MODELS USED ON SERIES
7956-336P Gas Valve All 856, 859
7966-311P Blower Motor for heat only All 856, 859
1468-235P/A Blower Motor for heat and a/c All 856, 859
2631-3481 Thermocouple All All
7660-3591 Upper Limit Switch (O-150, C-130) 7654, 7656B, 7663B, 7670B, 856, 859
7680-3791 Upper Limit Switch (O-140, C-120) 7680B 856, 859
7975-3281 Fan Switch (O-90, C-110) 7654, 7655, 7656B, 7663B, 7670B, 7680B, 7656F 856, 859
7710-3281 Fan Switch (O-85, C-105) 7665, 7670C, 7680C 856, 859
7680-3591 Lower Limit Switch (O-155, C-135) 7654, 7656B, 7656F, 7663B, 7680B 856, 859
7660-3591 Lower Limit Switch (O-150, C-130) 7665, 7670B, 7670B, 7680C 856, 859
7705-3591 Lower Limit Switch (O-145, C-125) 7655 856, 859
2940A3541 Transformer 115/24V, 40VA All 856, 859
No Longer Available Burner Assembly All 856, 859

Click here for Coleman Furnace Parts
Click here for Furnace Troubleshooting Help


Other Popular Articles

Leave a Comment